2017
DOI: 10.1049/joe.2017.0773
|View full text |Cite
|
Sign up to set email alerts
|

Fault characteristics of full power inverted sources and its short‐circuit current calculation model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Chi et al proposed a computational model for simulating the current fault problem and performed a parametric algorithm for it. In the course of their research, they verified the practical utility of the model through simulation experiments [4]. e mentioned researchers have made a detailed description of the short-circuit current calculation of related photovoltaic power plants, but there is no clear description of the construction of their models and the use of related algorithms.…”
Section: Introductionmentioning
confidence: 99%
“…Chi et al proposed a computational model for simulating the current fault problem and performed a parametric algorithm for it. In the course of their research, they verified the practical utility of the model through simulation experiments [4]. e mentioned researchers have made a detailed description of the short-circuit current calculation of related photovoltaic power plants, but there is no clear description of the construction of their models and the use of related algorithms.…”
Section: Introductionmentioning
confidence: 99%
“…Te transfer functions G 1 (s) and G 2 (s) in equation ( 2) are substituted into (13) and simplifed to obtain where i + α (t 0 ) and i + β (t 0 ) are the initial values of positive sequence currents output by GSC in the two-phase stationary coordinate frame at the fault moment; and f 1 (s) and f 2 (s) are the oscillation attenuation components generated in the simplifcation process, and the specifc expressions can be expressed as…”
Section: Circuit Equation In Dq-axis Coordinate Frame Of Positive Seq...mentioning
confidence: 99%
“…Te industry has also carried out extensive research and achieved some results in consideration of its important role in studying the action behavior of relay protection. On the basis of the comprehensive analysis of the converter power supply control system, a calculation model of the fault current of the converter power supply with a low-voltage ride-through control strategy is proposed in [13], and the transient short-circuit current of the converter power supply is calculated by using the transfer functions in the complex frequency domain of both the control system and converter [14], starting with the mathematical model of the control system, which describes the output current of the inverter after the fault in the form of second-order, constant coefcient diferential equations, and the current expression in the transient process is obtained analytically based on the steady-state value before and after the fault and the transient change law afected by the control parameters. Te authors of [15] describe the positive and negative sequence current after fault as second-order, constant coefcient diferential equations, and the short-circuit current expressions based on the independent control strategy of positive and negative sequence are derived.…”
Section: Introductionmentioning
confidence: 99%
“…If the active current is below the maximum allowed current, the remaining capacity is used to inject the reactive current. The available reactive current is given by Equation ( 13), and the effective multiplier is determined by Equation (14).…”
Section: Mode P-priority To the Active Power Injectionmentioning
confidence: 99%