2021 23rd European Conference on Power Electronics and Applications (EPE'21 ECCE Europe) 2021
DOI: 10.23919/epe21ecceeurope50061.2021.9570190
|View full text |Cite
|
Sign up to set email alerts
|

Fault Detection using Indirect DC Link Current Measurement Technique in Multiphase DC Converter with Coupled Inductor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…Kichan Kim presents an DC-DC converter for display driving system using op amp and pulse width modulation controller which fabricated with amorphous indium gallium zinc oxide thin film transistors [5]. Arturs Bogdanovs induced an indirect DC link current measurement technique for a multi-phase DC converter with coupled inductors, an op amp circuit is used in Arturs's approach as improve the DC link current waveform restoration quality [6]. This paper will discuss from the circuit construction to the numerical simulation about two uses: as an analogue computer, and as a proportional controlled DC motor having voltage to angle characteristic.…”
Section: Introductionmentioning
confidence: 99%
“…Kichan Kim presents an DC-DC converter for display driving system using op amp and pulse width modulation controller which fabricated with amorphous indium gallium zinc oxide thin film transistors [5]. Arturs Bogdanovs induced an indirect DC link current measurement technique for a multi-phase DC converter with coupled inductors, an op amp circuit is used in Arturs's approach as improve the DC link current waveform restoration quality [6]. This paper will discuss from the circuit construction to the numerical simulation about two uses: as an analogue computer, and as a proportional controlled DC motor having voltage to angle characteristic.…”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of the proposed method is adequate, the phase current misbalance is well represented by the ICM sensing signal and the measurement error is well below 0.5 A in the wide operation range. For more details, refer to [25].…”
Section: Indirect Current Measurement In Multi-phase DC Convertermentioning
confidence: 99%
“…Moreover, it can be extended for multiphase and multi-level inverters. A more detailed analysis is given in [36].…”
Section: Indirect Current Measurement In Multi-level Invertermentioning
confidence: 99%
See 1 more Smart Citation