2018
DOI: 10.1016/j.ijepes.2017.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Fault tolerance of the bidirectional trans quasi-Z-source inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Because of the complete symmetry of the circuit, the circuit operation is the same either way, and so here we discuss the analysis of forward power transfer only. In addition, the DC source/ or load can be either current or voltage source/ or load due to impedance source network [13,19] . When transferring power from U 1 to U 2 , S i (i = 1, 2, 3, 4) and SW 2 are turned on and all the other switches are turned off.…”
Section: Operation Mode Of Qzibdcmentioning
confidence: 99%
“…Because of the complete symmetry of the circuit, the circuit operation is the same either way, and so here we discuss the analysis of forward power transfer only. In addition, the DC source/ or load can be either current or voltage source/ or load due to impedance source network [13,19] . When transferring power from U 1 to U 2 , S i (i = 1, 2, 3, 4) and SW 2 are turned on and all the other switches are turned off.…”
Section: Operation Mode Of Qzibdcmentioning
confidence: 99%
“…One of the advances in ZSI topologies is the addition of magnetically coupled inductors in the impedance network, which improves the voltage boost capabilities and the modulation index, as well as reduces the number and the size of the passive elements in the impedance network [5]. Some of these improved configurations are the trans-ZSI [5], [6] and the improved trans-ZSI in [7]. The increase in the voltage boost of the converter achieved with the modulation techniques in [3], [8] is modest, while the configurations presented in [7], [9] have very high current and voltage levels.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, in order to improve the stability, security and reliability of the network control system, fully and reasonably utilize network resources, and use fault-tolerant control methods to ensure that the system can still work normally and stably in the event of component failures, network failures and external disturbances. Very important theoretical significance and practical application value [8]. Now, although some system control model literatures are based on neural networks, the unreliable factors of distributed systems are not fully considered.…”
Section: Introductionmentioning
confidence: 99%