Fault Tolerant Control of Five-Level Inverter Based on Redundancy Space Vector Optimization and Topology Reconfigruation

Abstract: Compared with two-level and three-level inverters, five-level inverters have more redundant space vectors to implement flexible control strategy. A fault tolerance method for open circuit fault of power tube in Neutral Point Clamped (NPC) five level inverter is proposed. The open circuit fault of inverter is divided into type Ⅰ and type Ⅱ in this paper. Redundant space vector optimization and topological reconfiguration fault tolerance strategies are used for type I and type II failures, respectively. The basi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…In Khanaki et al, 2019, the author integrated a single inverter into an extra low-voltage (ELV) battery module and modularized it and compared the reliability of the 48 V battery module with different redundancy strategies through experiments. In Yu et al, 2020, a five-level inverter single-tube open-circuit fault tolerance method based on redundant space vector optimization and topology reconstruction was proposed, and a new fault circuit space vector pulse width modulation control strategy was obtained, but the maximum output voltage of the inverter will be reduced to 3/4 of the normal inverter voltage. For many types of multilevel circuits, the voltage will be reduced to some extent after the failure occurs (Lee and Lee, 2016;Lee and Lai, 2021;Guan and Liu, 1109).…”
Section: Introductionmentioning
confidence: 99%
“…In Khanaki et al, 2019, the author integrated a single inverter into an extra low-voltage (ELV) battery module and modularized it and compared the reliability of the 48 V battery module with different redundancy strategies through experiments. In Yu et al, 2020, a five-level inverter single-tube open-circuit fault tolerance method based on redundant space vector optimization and topology reconstruction was proposed, and a new fault circuit space vector pulse width modulation control strategy was obtained, but the maximum output voltage of the inverter will be reduced to 3/4 of the normal inverter voltage. For many types of multilevel circuits, the voltage will be reduced to some extent after the failure occurs (Lee and Lee, 2016;Lee and Lai, 2021;Guan and Liu, 1109).…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, a complete correction of the fault is not always possible. This type of approach can be based solely on software adaptations, relying only on changes to the control and modulation strategies [21][22][23][24][25][26][27][28][29][30], or require some changes to the converter topology . Software-based fault correction presents the lowest possible complexity and cost but typically carries significant operational limitations, resulting in reduced post-fault performance.…”
Section: Introductionmentioning
confidence: 99%
“…In the case of inner IGBT faults, the effect of the fault can only be attenuated [23][24][25] since a large number of switching states is lost. In DC/AC applications, IGBT faults have a more severe impact on the NPC converter and cannot be fully corrected without topology changes, causing a derating [30].…”