2015
DOI: 10.1016/j.ejrad.2015.03.008
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility and evaluation of dual-source transmit 3D imaging of the orbits: Comparison to high-resolution conventional MRI at 3T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 27 publications
0
10
0
Order By: Relevance
“…The diagnosis-related parameters were measured in a single intracranial artery steno-occlusion with measureable wall NEURORADIOLOGY: Intracranial Artery Steno-Occlusion Chung et al ratio (25). However, importantly, the diagnosis of intracranial artery stenoocclusion was not significantly affected by the decreased image quality of zoomed MR imaging in our study.…”
Section: Comparison Of Diagnosis-related Parameters Between Full-fov mentioning
confidence: 51%
“…The diagnosis-related parameters were measured in a single intracranial artery steno-occlusion with measureable wall NEURORADIOLOGY: Intracranial Artery Steno-Occlusion Chung et al ratio (25). However, importantly, the diagnosis of intracranial artery stenoocclusion was not significantly affected by the decreased image quality of zoomed MR imaging in our study.…”
Section: Comparison Of Diagnosis-related Parameters Between Full-fov mentioning
confidence: 51%
“…Although DTI plays a key role in studying the integrity of microstructure and macrostructure of white matter tracts, existing distortion increased the challenge in its application in spinal cords. Current data acquisition methods mainly include parallel imaging and local enhancement shimming to reduce tissue‐induced susceptibility inhomogeneity distortion . However, these methods cannot thoroughly remove artifacts, and distortion still exists in spinal cord data, which may lead to false conclusions in potential SCI research.…”
Section: Discussionmentioning
confidence: 99%
“…It enables local B1-shimming so that the excitation of interested volume exhibits improved homogeneity to enhance spatial resolution, and significantly shortens the length of the echo train of echo-planar imaging sequence to reduce scanning time without causing additional fold-over artifact. 18,19 Riffel et al 19 used the inner-volume imaging technique to obtain diffusion-weighted images (DWI) of the heads and necks of healthy volunteers, gained a better image quality of zoomed DWI compared with traditional DWI. Seeger et al 20 conducted zoomed DWI scanning for patients with acute spinal cord ischemia injury and acquired a more detailed injury status than traditional DWI.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, even with the combination of T1 3D subtraction technique, the presence of contrast enhancement still resulted in misclassification in some cases. These errors may be further improved by the application of more advanced imaging techniques such as 3D CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) (38), compressed sensing (39), or reduced field-of-view imaging (40,41), which can provide higher spatial resolution without increasing scan time.…”
Section: Discussionmentioning
confidence: 99%