Optical Coherence Tomography and Coherence Techniques II 2005
DOI: 10.1364/ecbo.2005.mf4
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of a Compact Fiberoptic Probe for Real Time Tracing of Subsurface Skin Birefringence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2007
2007
2008
2008

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…As described in Fig. 1(b), either of these components the readout interferometer compensates optical path length differences in the sensing interferometer within a given interval of depth in the sample, and evolves spatial fringes which are read out by optoelectronic means without any mechanical scanning in depth [4].…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…As described in Fig. 1(b), either of these components the readout interferometer compensates optical path length differences in the sensing interferometer within a given interval of depth in the sample, and evolves spatial fringes which are read out by optoelectronic means without any mechanical scanning in depth [4].…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…In some practical cases, the zero-order interference fringe should be shifted from the center of the WP aperture. For that, it is necessary to change the relative thicknesses of the wedges 12 or insert in front or behind WP, a birefringent plate, which is cheaper. 23 At the design stage, a required position of L can be present beneath the sample surface by choosing the proper plate thickness.…”
Section: Basic Principlementioning
confidence: 99%
“…Before now, we made just speculative attacks on this challenge. 12,13 Here, we reveal the basic principle and consider in more detail the experimental verification of the specific solution proposed for such systems as well as mention the simplified algorithm for mapping birefringence of dermis through measurements of the depolarization ratio. 14…”
Section: Introductionmentioning
confidence: 99%
“…Seemingly, the first attempt to embody the aforesaid concept in a PS OCT system has been undertaken recently 20 . The "proof-of-concept" was outlined for the system which is, in fact, a tandem of the sensing Michelson interferometer with the fixed reference mirror and the readout interferometer based on Wollaston prism of special design.…”
Section: Qualitative Theorymentioning
confidence: 99%