2020
DOI: 10.1016/j.hlc.2019.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of Device Closure for Multiple Atrial Septal Defects With an Inferior Sinus Venosus Defect: Procedural Planning Using Three-Dimensional Printed Models

Abstract: Background Multiple atrial septal defects (ASD) with an inferior sinus venosus defect (SVD) have always been considered to be contraindications for interventional therapy. On the basis of early experience using a patent ductus arteriosus (PDA) occluder for interventional treatment for inferior ASD, this study investigated the feasibility of transcatheter closure of multiple ASDs with an inferior SVD under the guidance of threedimensional (3D) printed heart models.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
4
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 11 publications
0
9
0
1
Order By: Relevance
“…3DP cardiovascular models provide surgeons with impressive insights and better understanding of the location and size of lesions, which cannot be achieved with 2D images. However, previous studies were focused on forming rigid anatomical models made of hard polymers (16)(17)(18)(19)(20)(21), whereas a 3DP dynamic model made of flexible silicone can offer more detailed information concerning hemodynamics. Although CFD has also been applied for mitral repair simulation in previous research, models of the left heart system are often simplified and derived from only one modality (e.g., MRI) (22).…”
Section: Discussionmentioning
confidence: 99%
“…3DP cardiovascular models provide surgeons with impressive insights and better understanding of the location and size of lesions, which cannot be achieved with 2D images. However, previous studies were focused on forming rigid anatomical models made of hard polymers (16)(17)(18)(19)(20)(21), whereas a 3DP dynamic model made of flexible silicone can offer more detailed information concerning hemodynamics. Although CFD has also been applied for mitral repair simulation in previous research, models of the left heart system are often simplified and derived from only one modality (e.g., MRI) (22).…”
Section: Discussionmentioning
confidence: 99%
“…Dr. He reported similar success in subsequent cases (10) with only 5 cases and the description of the structure is vague.…”
Section: Introductionmentioning
confidence: 93%
“…Unsuitability of the procedure included the connection of the anomalous pulmonary vein(s) to the superior vena cava well above the right atrial junction or along the anterior wall, potential pulmonary venous compression with stenting and large defects. Catheter treatment of the inferior sinus venosus defects has been regarded unfeasible with only a few cases reported in the literature [73,74].…”
Section: Other Rare Defects Involving the Limbus Of The Fossa Ovalismentioning