2022
DOI: 10.3389/fcvm.2022.903203
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of one breath-hold cardiovascular magnetic resonance compressed sensing cine for left ventricular strain analysis

Abstract: ObjectiveTo investigate the feasibility of 3D left ventricular global and regional strain by using one breath-hold (BH) compressed sensing cine (CSC) protocol and determine the agreement between CSC and conventional cine (CC) protocols.MethodsA total of 30 volunteers were enrolled in this study. Cardiovascular magnetic resonance (CMR) images were acquired using a 1.436 T magnetic resonance imaging (MRI) system. The CSC protocols included one BH CSC and the shortest BH CSC protocols with different parameters an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 36 publications
0
2
0
Order By: Relevance
“…This observation suggests that the CS cine, used in our study as a single breath-hold high-speed technique, may not furnish equivalent strain values for patients with various cardiovascular conditions even with almost the same acquisition parameters (see Table 1). This discovery fails to replicate the strain value comparison results observed in other studies between CS-based cine and conventional cine, which demonstrate only minor differences (23)(24)(25). The accurate functioning of the FT algorithm is heavily reliant on achieving a high contrast between the blood and myocardium (26).…”
Section: Discussionmentioning
confidence: 75%
“…This observation suggests that the CS cine, used in our study as a single breath-hold high-speed technique, may not furnish equivalent strain values for patients with various cardiovascular conditions even with almost the same acquisition parameters (see Table 1). This discovery fails to replicate the strain value comparison results observed in other studies between CS-based cine and conventional cine, which demonstrate only minor differences (23)(24)(25). The accurate functioning of the FT algorithm is heavily reliant on achieving a high contrast between the blood and myocardium (26).…”
Section: Discussionmentioning
confidence: 75%
“…We also acknowledge our limited ability to detect possible publication bias due to the small number of studies. Lastly, CS methods have been applied to 3D cine which can provide comparable left ventricular functional and morphological assessment [ 41 ]. The current meta-analysis only examined CS application to 2D cine.…”
Section: Discussionmentioning
confidence: 99%