2019
DOI: 10.1101/805580
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Feasibility of spiral fMRI based on an LTI gradient model

Abstract: Highlights• This work investigates the feasibility of using a one-time system calibration (called GIRF) based on a linear time-invariant gradient model to account for k-space trajectory deviations in spiral fMRI.• We show that the image quality and the spatial specificity of the fMRI activation are substantially improved when using the GIRF-prediction for trajectory correction while the nominal reconstructions suffer from artifacts and mis-placed fMRI activation.• We demonstrate that system characterization vi… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 50 publications
0
4
0
Order By: Relevance
“…Spiral readouts provide high sampling efficiency with flexible TE and are well suited for fast acquisitions such as cardiac imaging, 40 and CBF measurements 32 and are considered a promising alternative to EPI readouts for fMRI. 41,42 However, without concomitant field compensation spatial blurring and signal loss were evident in this study, limiting usability as artifact-free images with high spatial conspicuity are paramount for clinical use.…”
Section: Discussionmentioning
confidence: 80%
See 1 more Smart Citation
“…Spiral readouts provide high sampling efficiency with flexible TE and are well suited for fast acquisitions such as cardiac imaging, 40 and CBF measurements 32 and are considered a promising alternative to EPI readouts for fMRI. 41,42 However, without concomitant field compensation spatial blurring and signal loss were evident in this study, limiting usability as artifact-free images with high spatial conspicuity are paramount for clinical use.…”
Section: Discussionmentioning
confidence: 80%
“…Concomitant field effects, if uncorrected, manifest as spatial blurring in spiral acquisitions, residual phase errors in phase contrast MRI, global shifts in EPI based sequences and inadequate slice compensation. Spiral readouts provide high sampling efficiency with flexible TE and are well suited for fast acquisitions such as cardiac imaging, 40 and CBF measurements 32 and are considered a promising alternative to EPI readouts for fMRI 41,42 . However, without concomitant field compensation spatial blurring and signal loss were evident in this study, limiting usability as artifact‐free images with high spatial conspicuity are paramount for clinical use.…”
Section: Discussionmentioning
confidence: 98%
“…We can therefore rule out temperature-related LTI violations as a cause for the observed discrepancies. Temperature effects might become relevant in imaging applications with high gradient duty cycles and long readout durations, for example fMRI 16 or DWI. 35 Shifts of the mechanical resonances with rising temperature 21,33,34 could compromise the long-term trajectory predictions of the GSTF.…”
Section: Discussionmentioning
confidence: 99%
“…Its first-order terms can be used to calculate actual k-space trajectories and apply them in image-reconstruction algorithms, [11][12][13] or to achieve a superior gradient pre-emphasis. 14,15 The GSTF-based correction methods have, for example, recently been shown to enable the use of spiral trajectories for functional 16 or real-time imaging. 17,18 The GSTF can be determined from the field response to a broadband input waveform.…”
Section: Introductionmentioning