2011
DOI: 10.1088/0741-3335/53/11/115003
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility study for a correlation electron cyclotron emission turbulence diagnostic based on nonlinear gyrokinetic simulations

Abstract: Abstract. This paper describes the use of nonlinear gyrokinetic simulations to assess the feasibility of a new correlation electron cyclotron emission (CECE) diagnostic that has been proposed for the . The simulations are used to predict ranges of fluctuation level, peak poloidal wavenumber and radial correlation length of electron temperature fluctuations in the core of the plasma. The impact of antenna pattern and poloidal viewing location on measurable turbulence characteristics is addressed using synthetic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…In the first measurements of long wavelength (k y q s < 0.3) electron temperature fluctuations in Alcator CMod made with a new correlation electron cyclotron emission diagnostic 281 electron temperature fluctuations decrease significantly ($40%) crossing from LOC to SOC, consistent with a change from TEM turbulence domination to ion temperature gradient (ITG) turbulence as the density and collisionality is increased. 221 Linear stability analysis shows that TEMs are dominant for long wavelength turbulence in the LOC regime and the ITG modes are dominant in the SOC regime at the radial location (q $ 0.8) where the changes in electron temperature fluctuations are measured.…”
mentioning
confidence: 97%
“…In the first measurements of long wavelength (k y q s < 0.3) electron temperature fluctuations in Alcator CMod made with a new correlation electron cyclotron emission diagnostic 281 electron temperature fluctuations decrease significantly ($40%) crossing from LOC to SOC, consistent with a change from TEM turbulence domination to ion temperature gradient (ITG) turbulence as the density and collisionality is increased. 221 Linear stability analysis shows that TEMs are dominant for long wavelength turbulence in the LOC regime and the ITG modes are dominant in the SOC regime at the radial location (q $ 0.8) where the changes in electron temperature fluctuations are measured.…”
mentioning
confidence: 97%
“…The components in the RF section and the first amplifier for 2-18 GHz signals are installed in front of the diagnostic port as shown in Figure 2(b). The current CECE IF section has 8 channels, two of which are tunable (6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). More details about Correlation ECE diagnostic in C-Mod can be found in [5] and upgrades in the IF section will be published in the future [6].…”
Section: Description Of the Correlation Ece Diagnostic In Alcator C-modmentioning
confidence: 99%
“…More details about Correlation ECE diagnostic in C-Mod can be found in [5] and upgrades in the IF section will be published in the future [6]. High poloidal resolution (k θ < 9.8 cm −1 ) with CECE at C-Mod is possible due to a small beam spot size (beam diameter, d < 1 cm), and was one of the important design considerations for the diagnostic [7]. Figure 3 shows the theoretical beam pattern in the poloidal direction based on the optical components such as in-vessel mirror and ex-vessel lens.…”
Section: Description Of the Correlation Ece Diagnostic In Alcator C-modmentioning
confidence: 99%
“…Gyrokinetic simulations have provided several constraints on the design of CECE for C-Mod. [8] First, the optical system should provide a small beam diameter (1/e electric field diameter) of 1cm at the measurement position to measure long wavelength (k θ ρ s <0.5) fluctuations in the core. The beam diameter determines poloidal spatial resolution of CECE, and a large beam diameter will result in filtering out of high frequency fluctuations.…”
Section: Design Of Cece Diagnostic In C-modmentioning
confidence: 99%
“…[6] Nonlinear gyrokinetic simulations using the GYRO code [7] were used to reexamine reasons for this, and the results motivate a new CECE diagnostic in C-Mod. [8] In this paper, the system overview and first results from the new CECE diagnostic on C-Mod are presented.…”
Section: Introductionmentioning
confidence: 99%