2017
DOI: 10.1088/1748-0221/12/11/c11022
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility study of direct spectra measurements for Thomson scattered signals for KSTAR fusion-grade plasmas

Abstract: Feasibility study of direct spectra measurements of Thomson scattered photons for fusion-grade plasmas is performed based on a forward model of the KSTAR Thomson scattering system. Expected spectra in the forward model are calculated based on Selden function including the relativistic polarization correction. Noise in the signal is modeled with photon noise and Gaussian electrical noise. Electron temperature and density are inferred using Bayesian probability theory. Based on bias error, full width at half max… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 18 publications
0
2
0
Order By: Relevance
“…The FIR interferometer diagnostic system provides line integrated electron densities, i.e., no spatial resolution, without such calibration factors [23,24,25,26]. Bayesian analysis for Thomson scattering [9,27,28], interferometer [5,29] systems and joint , the parameters we wish to determine, and observations are shown as red and blue circles, respectively. Note that the observations can be taken from previous inference, e.g., an observed Thomson scattered amplitude D TS is taken from the inference results described in Section 3.1.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The FIR interferometer diagnostic system provides line integrated electron densities, i.e., no spatial resolution, without such calibration factors [23,24,25,26]. Bayesian analysis for Thomson scattering [9,27,28], interferometer [5,29] systems and joint , the parameters we wish to determine, and observations are shown as red and blue circles, respectively. Note that the observations can be taken from previous inference, e.g., an observed Thomson scattered amplitude D TS is taken from the inference results described in Section 3.1.…”
Section: Introductionmentioning
confidence: 99%
“…no spatial resolution, without such calibration factors [23][24][25][26]. Bayesian analysis for Thomson scattering [9,27,28], interferometer [5,29] systems and joint analysis [30] have been previously reported. They made impressive progress, especially evaluating uncertainties of electron temperature and density.…”
mentioning
confidence: 99%