2020
DOI: 10.1016/j.avsg.2020.06.009
|View full text |Cite
|
Sign up to set email alerts
|

Fenestrated and Scalloped Endovascular Grafts in Zone 0 and Zone 1 for Aortic Arch Disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(34 citation statements)
references
References 22 publications
0
33
0
1
Order By: Relevance
“…Furuta et al [ 1 ] reported a recent and large experience with the use of fenestrated stent grafts: among 205 aortic repairs, 7 type IA endoleaks occurred, with a 3.4% incidence. Fernandez-Alonso et al [ 13 ] described 1 type IA endoleak among 14 patients, but it was not detectable at discharge. Canaud et al [ 14 , 15 ] (with two patient samples, one of 35 patients and one of 17), Tsilimparis et al [ 20 ] (44 patients), Tan et al [ 19 ] (7 patients), Yap et al [ 21 ] (5 repairs), Zhou et al [ 22 ] (42 patients), and Zhu et al [ 23 ] (10 patients) all reported the absence of endoleaks in their samples both at discharge and at follow-up.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Furuta et al [ 1 ] reported a recent and large experience with the use of fenestrated stent grafts: among 205 aortic repairs, 7 type IA endoleaks occurred, with a 3.4% incidence. Fernandez-Alonso et al [ 13 ] described 1 type IA endoleak among 14 patients, but it was not detectable at discharge. Canaud et al [ 14 , 15 ] (with two patient samples, one of 35 patients and one of 17), Tsilimparis et al [ 20 ] (44 patients), Tan et al [ 19 ] (7 patients), Yap et al [ 21 ] (5 repairs), Zhou et al [ 22 ] (42 patients), and Zhu et al [ 23 ] (10 patients) all reported the absence of endoleaks in their samples both at discharge and at follow-up.…”
Section: Resultsmentioning
confidence: 99%
“…Out of the 48 studies selected: 10 [ 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 ] described outcomes in chimney procedures, 13 [ 1 , 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 ] with the use of fenestrated devices, 9 [ 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 ] focused on in situ fenestration outcomes, 14 [ 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 ] on branched devices, one study compared fenestrated and branched devices [ 48 ], and one compared in situ fenestration and the chimney technique [ 49 ].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As mentioned, the short distance between the pseudoaneurysm entry tear and the IA branch-off presented a challenge for SG selection. Several techniques have been described for ascending aortic pathologies with landing zones too short to deploy a conventional SG, including fenestrated TEVAR [ 21 ], IA debranching and Ishimaru zone 0 TEVAR with a single chimney to the IA [ 3 ], closing the pseudoaneurysm using an Amplatz Type II or Type III vascular plug (AVP) only, or first coil embolizing the pseudoaneurysm followed by AVP insertion [ 22 ], and even a novel Endo-Bentall procedure [ 23 ]. In our case, the short landing zone challenge was overcome by selecting an off-the-shelf SG of the appropriate dimensions and by careful deployment preplanning to ensure continued patency of the IA.…”
Section: Discussionmentioning
confidence: 99%
“…Im vergangenen Jahrzehnt trug dazu vorwiegend ihre Verwendung in der endovaskulären Aortenbogenchirurgie bei, wo sie sich zur ersten Option entwickelt haben mit einer größeren Evidenz als bspw. fenestrierte Aortenbogenprothesen [26,27,28].…”
Section: Fazit Und Ausblickunclassified