Fibrinogen measurement in cardiac surgery with cardiopulmonary bypass: Analysis of repeatability and agreement of Clauss method within and between six different laboratories

Abstract: SummaryPlasma fibrinogen concentration is important for coagulopathy assessment, and is most commonly measured using the Clauss method. Several factors, including device type and reagent, have been shown to affect results. The study objective was to evaluate performance and repeatability of the Clauss method and to assess differences between measurements performed during and after cardiopulmonary bypass (CPB), by testing plasma samples from patients undergoing cardiac surgery with CPB. Samples were collected f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 41 publications
(13 citation statements)
references
References 31 publications
(47 reference statements)
0
13
0
Order By: Relevance
“…The former was ascribed to an unexplained interference with the optical source by hydroxyethyl starch and the latter was due to impairment of fibrin polymerization induced by the fluid. In addition, the fibrinogen measurement by the Clauss method for the same set of plasma samples can vary within and between laboratories [94].…”
Section: Measurement Of Fibrinogen Levels and Functionsmentioning
confidence: 99%
“…The former was ascribed to an unexplained interference with the optical source by hydroxyethyl starch and the latter was due to impairment of fibrin polymerization induced by the fluid. In addition, the fibrinogen measurement by the Clauss method for the same set of plasma samples can vary within and between laboratories [94].…”
Section: Measurement Of Fibrinogen Levels and Functionsmentioning
confidence: 99%
“…All samples were immediately refrigerated and transported to the Department of Clinical Laboratory for determining lipid profiles, FBG, glycosylated hemoglobin A1c (HbA1c), high-sensitive C-reactive protein (hs-CRP), blood urea nitrogen (BUN), creatinine, uric acid and a spectrum of hematological and liver functional tests by standard laboratory techniques on a Hitachi 912 Analyzer (Roche Diagnostics, Germany). Serum Fg level was determined using the Clauss method as previously reported,[ 19 ] and FDP level (including D and E fragments, D-dimer, and additional intermediate cleavage products) was assessed by a sandwich immunoassay. The Fg/FDP ratio was then calculated.…”
Section: Ethodsmentioning
confidence: 99%
“…are familiar to pathologists and laboratorians alike, the approach to demonstrating similarity between data sets is often less well-defined. Some studies rely exclusively on the correlation coefficient to establish statistical similarity; however,[ 12 13 14 15 16 17 ] the combination of the correlation coefficient with Bland–Altman analysis is a more stringent approach to demonstrating functional equivalence between a novel and an established method and is subject to fewer sources of error. [ 9 10 12 13 16 ] The superiority of a combined approach is evidenced by our results for peripheral blood basophils: Although only moderate correlation was observed for this cell category ( r = 0.684; Figure 2f , upper panel), the accompanying Bland–Altman analysis [ Figure 2f , lower panel] demonstrated that this lack of correlation does not represent a systematic discrepancy between the two methods.…”
Section: Discussionmentioning
confidence: 99%