PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409)
DOI: 10.1109/icpst.2000.898161
|View full text |Cite
|
Sign up to set email alerts
|

Field experience with the new platform-mounted DVR/sup TM/

Abstract: Installation of the world's first Platform-Mounted Dynamic Voltage Restorer (DVRTM PM) prototype on a major North American utility system to protect a critical customer load from power system voltage disturbances ushers in a new era of power quality solutions available for overhead distribution systems on the utility side of the revenue billing meter. The DVRTM PM built by Siemens for the Electric Power Research Institute (EPRI) was installed at the Northem Lights Community College in Dawson Creek, B.C. where … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(1 citation statement)
references
References 2 publications
0
1
0
Order By: Relevance
“…Nanyang Technological University Library the PCC. During a downstream faul~, passive control method is often used to control the DVR by enabling the bypass circuit (usually a slow mechanical bypass together with a fast solid-state switch)[68,70,71] and protecting the DVR from the fault current, while allowing the• large fault current to flow which could cause the PCC voltage to drop.Active control of series connected device during a fault by limiting the fault current is reported in[72,73] and Chapter 5. Compared to the passive protection of DVR, active control of DVR during a downstream fault makes the additional protection circuits unnecessary and the implementation easy.…”
mentioning
confidence: 99%
“…Nanyang Technological University Library the PCC. During a downstream faul~, passive control method is often used to control the DVR by enabling the bypass circuit (usually a slow mechanical bypass together with a fast solid-state switch)[68,70,71] and protecting the DVR from the fault current, while allowing the• large fault current to flow which could cause the PCC voltage to drop.Active control of series connected device during a fault by limiting the fault current is reported in[72,73] and Chapter 5. Compared to the passive protection of DVR, active control of DVR during a downstream fault makes the additional protection circuits unnecessary and the implementation easy.…”
mentioning
confidence: 99%