Field mapping without reference scan using asymmetric echo-planar techniques

Abstract: in B 0 mapping and shimming were achieved by measuring the static field information in multiple subsequent echoes generated by an asymmetric echo-planar readout gradient train. With careful compensation, eddy current effects were shown to affect the adjustment of the shim coils minimally. In addition to reducing the time required for field mapping by two-fold, the sensitivity was simultaneously optimized irrespective of the prevalent T* 2 present, thereby minimizing the error of the static field measurement to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
472
1

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
3

Relationship

5
5

Authors

Journals

citations
Cited by 545 publications
(474 citation statements)
references
References 15 publications
1
472
1
Order By: Relevance
“…3). First-and second-order shims were adjusted using FAST(EST)MAP (shim volume = 22 × 25 × 22 mm 3 ) (Gruetter, 1993;Gruetter and Tkac, 2000). Flip angles of the water suppression pulses were optimized to reduce the residual water peak height below that of NAA.…”
Section: Mr Protocolmentioning
confidence: 99%
“…3). First-and second-order shims were adjusted using FAST(EST)MAP (shim volume = 22 × 25 × 22 mm 3 ) (Gruetter, 1993;Gruetter and Tkac, 2000). Flip angles of the water suppression pulses were optimized to reduce the residual water peak height below that of NAA.…”
Section: Mr Protocolmentioning
confidence: 99%
“…The mouse brain was positioned in the isocenter of the magnet and located with fast-spin-echo images with repetition time of 4 seconds, echo time of 52 ms, and echo train length of 8. Field homogeneity in the region of interest was achieved with FAST(EST)MAP (Gruetter, 1993;Gruetter and Tkác, 2000). Volumes of interest were placed in the hippocampus Fig.…”
Section: Mrsmentioning
confidence: 99%
“…The cardiac trigger was typically send 50 or 60 ms after the maximum observed blood pressure. Cardiac triggered and respiratory gated shimming was performed to reduce the localized proton line width in a myocardial voxel of 4 × 5 × 5 mm 3 to 20-30 Hz using a triggered FASTESTMAP sequence [41], resulting in a non-localized proton line width of 80-120 Hz. The spectrometer was triggered to start acquisition at the beginning of the automated injection process.…”
Section: In Vivo Mri and Mrsmentioning
confidence: 99%