Field measurement and energy efficiency enhancement potential of a seawater source heat pump district heating system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…The heat pump used to capture waste heat from the data centre Except for the inherent performance characteristics of the HP, the operational conditions are the main factors that influence the energy performance of an HP [44]. The operational conditions include the inlet and outlet water temperature and the water mass flow rate on the evaporator and condenser sides of an HP [45]. Therefore, the HP compressor power may be expressed by a simple function involving the above mentioned operational conditions, as shown in Equation ( 11):…”
Section: Model For Data Centrementioning
confidence: 99%
“…The heat pump used to capture waste heat from the data centre Except for the inherent performance characteristics of the HP, the operational conditions are the main factors that influence the energy performance of an HP [44]. The operational conditions include the inlet and outlet water temperature and the water mass flow rate on the evaporator and condenser sides of an HP [45]. Therefore, the HP compressor power may be expressed by a simple function involving the above mentioned operational conditions, as shown in Equation ( 11):…”
Section: Model For Data Centrementioning
confidence: 99%
“…Meanwhile, corrosion and microbial attachment on heat exchanger may worsen the heat extraction ability of the heat pump unit. Seawater temperature is a critical factor influencing the energy efficiency of the heat pump, it is also important to prevent freezing when the outside is severely cold [37,38]. In order to extract heat more reliable, researchers suggested renovations in the heat exchange process [37,39].…”
Section: Literature Reviewmentioning
confidence: 99%
“…In this study, both SWHP and ASHP are assumed to cover full building heating/cooling load, so no supplementary heating/cooling is considered ( = T sup( ) 0 i ). Electricity consumption of circulation pump is assumed to account for 25% of total heat pump system electricity consumption according to [63]. For coal boilers, system efficiency is set to be 0.75 according to [64].…”
Section: Technical Key Performance Indicatorsmentioning
confidence: 99%