2016
DOI: 10.1016/j.enbuild.2015.11.049
|View full text |Cite
|
Sign up to set email alerts
|

Field measurements, assessments and improvement of Kang: Case study in rural northwest China

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(7 citation statements)
references
References 9 publications
0
6
0
1
Order By: Relevance
“…Most of the internal structures are connected by a pot table and Kang (Kang, usually made of masonry, adobe, and cement, serves as a traditional bed platform and heating system for rural Chinese people, as shown in Figure 2). By burning biomass inside the pot table for heating and cooking, the heat generated is transferred to the Kang, which in turn raises the room temperature (heat transfer between the Kang and the pot table is shown in Figure 2 [49]). Most of these buildings are 20-30 years old and with poor enclosing structure airtightness.…”
Section: Sites and Samplingmentioning
confidence: 99%
“…Most of the internal structures are connected by a pot table and Kang (Kang, usually made of masonry, adobe, and cement, serves as a traditional bed platform and heating system for rural Chinese people, as shown in Figure 2). By burning biomass inside the pot table for heating and cooking, the heat generated is transferred to the Kang, which in turn raises the room temperature (heat transfer between the Kang and the pot table is shown in Figure 2 [49]). Most of these buildings are 20-30 years old and with poor enclosing structure airtightness.…”
Section: Sites and Samplingmentioning
confidence: 99%
“…(Wang, Lin, and Su et al 2012) Research by Zhu, Wang, and Lin et al (2011) revealed that the smoke flow inside the hot-wall kang was more evenly distributed, and the room temperature was increased by 10-20°C. In the research of Li, Gao, and Yang (2016) a new model of a kang flue was proposed to improve both the thermal performance and energy efficiency.…”
Section: Improvement Of the Kss Structurementioning
confidence: 99%
“…[14], örnek bir Çin geleneksel konutunu hesaplamalı akışkanlar dinamiği yazılımı ile analiz ettikleri çalışmalarında açık bir şömine elemanının, yapının farklı yerlerinde konumlandığında, iç mekân ısıl durumunda ne türden değişikliklere neden olacağını göstermişlerdir. Bu araştırmalara ek olarak, tarihi ısıtma sistemlerini model almış [15][16][17][18] ve bu sistemlerin ısıl veriminin arttırılarak çağdaş tasarımlar için değerlendirilmesi konusuna odaklanmış çalışmalar da bu alanda katkı sağlayan araştırmalardır [19][20][21]. Bu çalışmaların yanı sıra, özellikle geleneksel ocak elemanını konu alan incelemeler oldukça sınırlıdır.…”
Section: Giriş (Introduction)unclassified