2018
DOI: 10.1016/j.partic.2017.08.001
|View full text |Cite
|
Sign up to set email alerts
|

Field study of a soft X-ray aerosol neutralizer combined with electrostatic classifiers for nanoparticle size distribution measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 35 publications
0
4
0
Order By: Relevance
“…Other work showed a good correlation in the particle number concentration and differences in the count median diameter and geometric standard deviation below 4% for a polydisperse NaCl aerosol measured with GRIMM SMPS equipped with either an X-ray source (TSI RX 3087) or a radioactive source (Nicosia et al, 2014). The results from Nicosia et al (2018) confirmed that instrumental uncertainties introduced by the use of the X-ray sources rather than a radioactive neutralizer in the size range 10-300 nm are negligible, in line with previous work published by Kallinger et al (2012).…”
Section: Experimental Setup and Smps Typesmentioning
confidence: 82%
“…Other work showed a good correlation in the particle number concentration and differences in the count median diameter and geometric standard deviation below 4% for a polydisperse NaCl aerosol measured with GRIMM SMPS equipped with either an X-ray source (TSI RX 3087) or a radioactive source (Nicosia et al, 2014). The results from Nicosia et al (2018) confirmed that instrumental uncertainties introduced by the use of the X-ray sources rather than a radioactive neutralizer in the size range 10-300 nm are negligible, in line with previous work published by Kallinger et al (2012).…”
Section: Experimental Setup and Smps Typesmentioning
confidence: 82%
“…It is worth noting that the elementary charge of each particle is assumed to be equal to 1. This assumption is based on the fact that in this study the particles with the diameter smaller than 50 nm are primarily capable of acquiring a single charge within the aerosol neutralizer [37,38].…”
Section: Discussionmentioning
confidence: 99%
“…5522). Nicosia et al [ 24 ], applied a TSI soft X-Ray neutralizer to the Grimm L-DMA column obtaining a transfer function to correct the data. The SMPS scan time was ca 4.5 min with a 1.5 min retrace time.…”
Section: Methodsmentioning
confidence: 99%