2012
DOI: 10.1016/j.solener.2012.05.020
|View full text |Cite
|
Sign up to set email alerts
|

Field thermal performance of naturally ventilated solar roof with PCM heat sink

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
69
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 128 publications
(76 citation statements)
references
References 11 publications
4
69
0
1
Order By: Relevance
“…The results were found to be in agreement with the previously reported literature findings [26,27]. In [26], a PCMintegrated, building-integrated photovoltaic system reduced roof-generated heating loads by 30% in the winter and cooling load by 55% in the summer. In [27], a wall outfitted with a PCM reduced space-cooling load by 10.4%.…”
Section: Reduction In Heat Gainsupporting
confidence: 91%
See 2 more Smart Citations
“…The results were found to be in agreement with the previously reported literature findings [26,27]. In [26], a PCMintegrated, building-integrated photovoltaic system reduced roof-generated heating loads by 30% in the winter and cooling load by 55% in the summer. In [27], a wall outfitted with a PCM reduced space-cooling load by 10.4%.…”
Section: Reduction In Heat Gainsupporting
confidence: 91%
“…The heat gain reduction was 44% by the block B and 10.5% by the block C on 24 h basis compared to the block A. The results were found to be in agreement with the previously reported literature findings [26,27]. In [26], a PCMintegrated, building-integrated photovoltaic system reduced roof-generated heating loads by 30% in the winter and cooling load by 55% in the summer.…”
Section: Reduction In Heat Gainsupporting
confidence: 90%
See 1 more Smart Citation
“…It should be noted, however, that the DSC heating/cooling rate of 1°C per minute is too high for characterizing PCMs for building applications as the temperature changes in real building envelopes occur at a much slower rate. A different heating/cooling rate can appreciably alter the observed melting and freezing temperature thresholds and ranges [3].…”
Section: Temperature and Heat Fluxmentioning
confidence: 99%
“…Ventilated roof performances are more remarkable than conventional roof in both summer and winter conditions [12,13]. Ventilated roof performances can be improved using upgrading systems as a function of different effects of summer and winter regimes [14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%