1985
DOI: 10.1111/j.1600-0765.1985.tb00416.x
|View full text |Cite
|
Sign up to set email alerts
|

Film‐holder device for radiographic assessment of periodontal tissues

Abstract: A method, combining the standardization of radiographs with consistent radiopaque marker placement using a controlled force, is presented. Ten adult volunteers with healthy mouths were selected. Customized radiographic film holders were fabricated consisting of a plastic stent of the maxillary or mandibular arches to which a radiographic bite‐block was attached. An orthodontic stainless steel tube was added and placed so that the radiographic marker could be guided repeatedly to the base of the sulcus in the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

1988
1988
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…The positions of ACL and CEJ were marked by a pencil on the radiographs and the distance ACL − CEJ (BL) was measured by a millimeter grid. Linear distances between the most coronal interproximal BL and the CEJ were obtained by counting the grids 28 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The positions of ACL and CEJ were marked by a pencil on the radiographs and the distance ACL − CEJ (BL) was measured by a millimeter grid. Linear distances between the most coronal interproximal BL and the CEJ were obtained by counting the grids 28 …”
Section: Methodsmentioning
confidence: 99%
“…Linear distances between the most coronal interproximal BL and the CEJ were obtained by counting the grids. 28…”
Section: Radiographic Measurementsmentioning
confidence: 99%
“…Radiographic measurements were obtained utilizing an adhesive millimeter grid (X‐Ray Grid 3–4 cm, Mey GmbH, Oberursel, Germany). Vertical linear distances between the CEJ and the most coronal interproximal extension of bone crest were obtained by counting the grids (Nery et al 1985). Initial bone loss as the inclusion criteria was assessed according to the position of the bone crest in relation to CEJ.…”
Section: Methodsmentioning
confidence: 99%
“…The intraoral film-holding devices for the paralleling technique are commercially available with numerous designs, and their advantages/disadvantages have been evaluated [ 17 , 18 , 19 , 20 , 21 ]. To the best of our knowledge, the film holders mostly comprise a film-holding portion and a right-angle beam aiming rod (with or without an aiming ring).…”
Section: Introductionmentioning
confidence: 99%