1975
DOI: 10.1021/ac60364a009
|View full text |Cite
|
Sign up to set email alerts
|

Filter sampling method for atmospheric sulfur dioxide at background concentrations

Abstract: 0.2mM were stable and sufficiently concentrated to give quantitative results. The thiocyanate concentration was found to be important in driving the reaction to completion and affected the rate of complex formation. Low absorbances observed at concentrations less than about 0.2M might, in part, result from the decomposition of I(SCN)zto form the non-absorbing ISCN (IO).Hydrogen ion concentrations were about 1M in all cases.Lower concentrations caused a slight decrease in stability and higher concentrations (ab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
8
0

Year Published

1977
1977
1994
1994

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…Although only indirectly related to sampling, descriptions of the treatment of the data in both papers are useful. Methods for sampling sulfur dioxide (29,152,224,241,503) and nitrogen dioxide (82,105) have been described. Husar and co-workers provided a good discussion of the sampling designs and equipment required when sampling for sulfur dioxide and sulfate particulates from an aircraft (224).…”
Section: Atmospherementioning
confidence: 99%
“…Although only indirectly related to sampling, descriptions of the treatment of the data in both papers are useful. Methods for sampling sulfur dioxide (29,152,224,241,503) and nitrogen dioxide (82,105) have been described. Husar and co-workers provided a good discussion of the sampling designs and equipment required when sampling for sulfur dioxide and sulfate particulates from an aircraft (224).…”
Section: Atmospherementioning
confidence: 99%
“…Therefore, quantitative measurements of atmospheric sulfur-containing gases at these ultratrace levels require an efficient sample preconcentration step prior to the actual detection phase. These sample enrichment techniques have included various types of chemically impregnated filters (1)(2)(3)(4)(5), solid adsorbents (6)(7)(8), metal-coated glass beads (9,10), and cryogenic traps (11)(12)(13)(14).…”
mentioning
confidence: 99%
“…In each test, one sample was analyzed immediately; the others were capped and stored at room temperature. Results in Table II indicate that less than 10% of N02 and S02 was lost in the sample after 4 days.…”
Section: Resultsmentioning
confidence: 99%