1980
DOI: 10.1016/0002-9394(80)90002-1
|View full text |Cite
|
Sign up to set email alerts
|

Filtering Valve Implant Surgery for Eyes with Neovascular Glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
17
1

Year Published

1984
1984
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(18 citation statements)
references
References 15 publications
0
17
1
Order By: Relevance
“…Loss of light perception was reported between 11 and 48% of eyes after tube implantation in NVG. [4][5][6][7] Second cause of failure was phitisis bulbi in three eyes (7.9%) in AGV group and four eyes (14.8%) in MSPI group in our study. Phthisis bulbi was secondary to progression of the proliferative retinopathy in all cases.…”
Section: Discussionmentioning
confidence: 85%
See 1 more Smart Citation
“…Loss of light perception was reported between 11 and 48% of eyes after tube implantation in NVG. [4][5][6][7] Second cause of failure was phitisis bulbi in three eyes (7.9%) in AGV group and four eyes (14.8%) in MSPI group in our study. Phthisis bulbi was secondary to progression of the proliferative retinopathy in all cases.…”
Section: Discussionmentioning
confidence: 85%
“…Artificial aqueous drainage devices have been advocated for primary surgical treatment of NVG but general success rates varied in different studies. [4][5][6][7][8] In this retrospective study, we evaluated 5-year efficacy and safety of Molteno singleplate implant (MSPI) without pressure ridge and Ahmed glaucoma valve (AGV) in eyes with NVG and examined the factors that influence the outcome.…”
Section: Introductionmentioning
confidence: 99%
“…A success rate of over 50% with both intraocu lar pressure control and visual acuity is there fore most encouraging and certainly com pares favourably with recent studies using a variety of drainage implants. 7,8,9,14,15,16,17,18,19,20,21 Consideration of visual acuity shows that a successful outcome is significantly less likely in the neovascular glaucomas. This does not relate directly to intraocular pressure control but appears to be due more to the continuing disease process.…”
Section: Discussionmentioning
confidence: 99%
“…!,2,3,4 Although the concept of enhanced drainage is not new, practical implementation has only recently gained acceptance, with the Molteno short tube implantS leading the way for further drainage implant development. 6,7,8 Aqueous may be re-routed in three ways by:…”
mentioning
confidence: 99%
“…Pre vious studies [1][2][3][4][5][6][7][8][9] have clearly shown the advantages of Krupin-Denver valve implantation in glaucoma surgery as well as the main complications and causes o f failure: hypotony in the early postoperative period, blockage of the in ternal fistula, blockage of the external fistula. Long-term results of Krupin-Denver valve implantation are often con-ditioned by the high mortality of patients [3].…”
Section: Introductionmentioning
confidence: 99%