2018
DOI: 10.1186/s12938-018-0588-z
|View full text |Cite
|
Sign up to set email alerts
|

Fine-grain recordings of the electrically evoked compound action potential amplitude growth function in cochlear implant recipients

Abstract: BackgroundIn cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech processor. In a standard clinical setup recordings are averaged over 25–100 repetitions to allow for the detection of ECAPs within the noise floor. To obtain an amplitude growth function, these measurements are normally performed for 5–10 different stimulation levels. We eva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 14 publications
0
20
1
Order By: Relevance
“…The amplitude of the single pulse electric stimulation in charge units (nC) was steadily increased in a continuous paradigm ( Gärtner et al., 2018 ). Upon reaching the loudest acceptable presentation level, which the subject indicated in real time, the stimulation of the current electrode was stopped.…”
Section: Methodsmentioning
confidence: 99%
“…The amplitude of the single pulse electric stimulation in charge units (nC) was steadily increased in a continuous paradigm ( Gärtner et al., 2018 ). Upon reaching the loudest acceptable presentation level, which the subject indicated in real time, the stimulation of the current electrode was stopped.…”
Section: Methodsmentioning
confidence: 99%
“…Measurements were recorded via the MAX Programming Interface (MED-EL Medical Electronics, Innsbruck, Austria) connected to a personal computer running the research software that is described in [ 7 ]. Symmetric charge-balanced biphasic pulses were used to elicit the nerve response.…”
Section: Methodsmentioning
confidence: 99%
“…This limits the resolution at which the ECAP threshold can be determined. This problem was addressed in the design of the FineGrain stimulation paradigm [ 7 ], which samples the AGF in smaller stimulus steps and thus provides the means to use the higher ECAP AGF resolution for more accurate ECAP threshold determination. As a further development of this idea, FineGrain was combined with an automatic threshold determination approach, available as AutoART in the MAESTRO software (MED-EL Medical Electronics, Innsbruck, Austria) since 2017, version 7 and higher [ 7 , 8 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Results from measurements taken by the AutoART task, benefitting from the fine-grain recording of the response [ 13 ], were additionally used in subject A-01. Only in this case, a different stimulation rate of 60 pps was used.…”
Section: Methodsmentioning
confidence: 99%