2018
DOI: 10.1186/s13018-018-0970-3
|View full text |Cite
|
Sign up to set email alerts
|

Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures

Abstract: BackgroundIn the present study, we evaluated the mechanical outcome of different configurations formed by fully threaded screws and partially threaded screws in the treatment of unstable femoral neck fracture.MethodsThe Pauwels type III unstable femoral fracture and the models of the fully threaded screw and partially threaded screw were constructed in 3-matic software and UG-NX software respectively. We then assembled the different screw configurations to the fracture model separately to form the fixation mod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
45
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 46 publications
(48 citation statements)
references
References 24 publications
3
45
0
Order By: Relevance
“…The triangular con guration was favorable compared with the inverted con guration. This result is consistent with those in previous studies 32,38 showing that triangular con guration xation is slightly better than inverted con guration xation. This result can be explained by the main nail and the antirotational screw providing excellent angular support and effectively maintaining the fracture in the appropriate position.…”
Section: Discussionsupporting
confidence: 94%
“…The triangular con guration was favorable compared with the inverted con guration. This result is consistent with those in previous studies 32,38 showing that triangular con guration xation is slightly better than inverted con guration xation. This result can be explained by the main nail and the antirotational screw providing excellent angular support and effectively maintaining the fracture in the appropriate position.…”
Section: Discussionsupporting
confidence: 94%
“…Different from the FE model of the pelvis and entire hip joint, the region of joint reaction force as well as the weight-bearing area in such separate model with standing position needs to be defined before stress loading. Most of the related literature present to design the weight-bearing area as an ambiguous elliptical region [23,24], or load the joint force by simplifying it into a point [19,25]. This can unify load condition and quickly realize the mechanical analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Different from the FE model of pelvis and entire hip joint, the region of joint reaction force as well as the weight-bearing area in such separate model with standing position needs to be defined before stress loading. Most of the related literature present to design weight-bearing area as an ambiguous elliptical region [19,20], or load the joint force by simplifying it into a point [15,21]. This can unify load condition and quickly realize the mechanical analysis.…”
Section: Discussionmentioning
confidence: 99%