2013
DOI: 10.1007/s10439-013-0851-1
|View full text |Cite
|
Sign up to set email alerts
|

Finite Element Analysis of the Multiple Drilling Technique for Early Osteonecrosis of the Femoral Head

Abstract: We used finite element (FE) method to investigate the effect of the drilling number and entry location of holes used in the multiple drilling technique on the stress and strain state in femur. Different three-dimensional FE models of a human hip joint with or without multiple drilling were fabricated using computed tomographic images obtained from the hip joint of a cadaver. The analysis technique was evaluated in a compression test using the cadaver specimen and FE analysis for the test using an FE model of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
27
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(28 citation statements)
references
References 27 publications
1
27
0
Order By: Relevance
“…The tenet for core decompression with 10-mm trephines 86, and percutaneous drilling 7,88,89,180,[193][194][195][196] is a reduction in intraosseous hypertension 197 . Favorable outcomes have been associated with hips with symptomatic, precollapse, smaller-sized lesions 196 .…”
Section: Core Decompressionmentioning
confidence: 99%
“…The tenet for core decompression with 10-mm trephines 86, and percutaneous drilling 7,88,89,180,[193][194][195][196] is a reduction in intraosseous hypertension 197 . Favorable outcomes have been associated with hips with symptomatic, precollapse, smaller-sized lesions 196 .…”
Section: Core Decompressionmentioning
confidence: 99%
“…As the data of osteonecrosis model is from a living patient, it cannot be verified by direct biomechanical experiment. Therefore, we compared the stress value and distribution with related researches [11,29], and the similar results were obtained. Meanwhile, the biomechanical experiments were promoted to verify the models from the side.…”
Section: Discussionmentioning
confidence: 74%
“…Cortical bone, cancellous bone, cartilage, and necrotic area were considered to be isotropic linear elastic materials. The material parameters in each structure were taken from following previous studies (Table 1) [23][24][25][26]. The mesh division of the bone structure of the hip joint was established using 10-node modified tetrahedron unit, and where cartilage was established using the hexahedron unit.…”
Section: Methodsmentioning
confidence: 99%
“…For loading conditions, single leg support (midstance phase), corresponded to 30% of the gait cycle as reported previously, was applied [23]. A compressive axial load of 570 N, which accounts for 5/6 of 70 kg body weight, was applied to the nodes of proximal acetabular bone [18,20].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation