2012
DOI: 10.1177/193229681200600419
|View full text |Cite
|
Sign up to set email alerts
|

First Clinical Evaluation of a New Long-Term Subconjunctival Glucose Sensor

Abstract: Abbreviations: (BG) blood glucose, (C 2 O 2 H 3 Na) sodium acetate, (CaCl 2) calcium dichloride, (Con A) Concanavalin A, (K 2 CO 3) dipotassium carbonate, (KCl) potassium chloride, (LED) light-emitting diode, (MgCl 2) magnesium dichloride, (NaCl) sodium chloride, (NaHCO 3) sodium hydrogencarbonate, (Na 2 HPO 4) disodium hydrogenphosphate, (NaSO 4) sodium sulfate, (OMI) ocular mini implant, (SGMS) subconjunctival glucose monitoring system, (UV) ultraviolet

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(22 citation statements)
references
References 31 publications
0
22
0
Order By: Relevance
“…The setup of the photometer is described in detail elsewhere. 26 The fluorescence photometer measures the intensity of fluorescent light emitted back by the OMI at two wavelengths, one of which correlates with glucose concentration while the other acts as a reference and independent of glucose concentration. The photometer contains a target light for the patient to look at, and its front shape is ergonomically designed to mechanically guide the patient in correctly placing the photometer in front of the face and the eye.…”
Section: Fluorescence Detection By the Handheld Photometermentioning
confidence: 99%
See 4 more Smart Citations
“…The setup of the photometer is described in detail elsewhere. 26 The fluorescence photometer measures the intensity of fluorescent light emitted back by the OMI at two wavelengths, one of which correlates with glucose concentration while the other acts as a reference and independent of glucose concentration. The photometer contains a target light for the patient to look at, and its front shape is ergonomically designed to mechanically guide the patient in correctly placing the photometer in front of the face and the eye.…”
Section: Fluorescence Detection By the Handheld Photometermentioning
confidence: 99%
“…As previously described, 26 the OMI was inserted under sterile conditions and after topical anesthesia under the temporal conjunctiva of the right eye of the patients. The edges of the incision were sutured.…”
Section: Ocular Mini Implant Implantation In Human Eyesmentioning
confidence: 99%
See 3 more Smart Citations