2021
DOI: 10.1016/j.fusengdes.2021.112659
|View full text |Cite
|
Sign up to set email alerts
|

First tests and commissioning of the emittance scanner for SPIDER

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…At present, the beam source is operated in pulsed mode and it is equipped with a number of beam diagnostics and source diagnostics (see [21] and references therein). The diagnostic calorimeter STRIKE [22], beam emission spectroscopy (BES) [23], optical cameras, Allison emittance scanner [24], single-beamlet current monitors (new diagnostics based on LEM sensors) provide independent measurements of the beam properties, while Langmuir probes [25], optical emission spectroscopy [26], cavity ring down spectroscopy [27], laser absorption spectroscopy [28], Langmuir-Tayor detectors [29] can provide insight on the plasma and surface processes inside the plasma source.…”
Section: Experimental Configuration Of Spider and Operation With Caesiummentioning
confidence: 99%
“…At present, the beam source is operated in pulsed mode and it is equipped with a number of beam diagnostics and source diagnostics (see [21] and references therein). The diagnostic calorimeter STRIKE [22], beam emission spectroscopy (BES) [23], optical cameras, Allison emittance scanner [24], single-beamlet current monitors (new diagnostics based on LEM sensors) provide independent measurements of the beam properties, while Langmuir probes [25], optical emission spectroscopy [26], cavity ring down spectroscopy [27], laser absorption spectroscopy [28], Langmuir-Tayor detectors [29] can provide insight on the plasma and surface processes inside the plasma source.…”
Section: Experimental Configuration Of Spider and Operation With Caesiummentioning
confidence: 99%
“…The angular velocity distribution of an isolated beamlet simultaneously measured by the Allison emittance scanner [35] (AES-left column) and the beam emission spectroscopy [36] (BES-right column) is shown in Fig. 10 for the previously mentioned plasma pulses.…”
Section: Beam Halo and Operation With Deuteriummentioning
confidence: 99%
“…This is essential to quantify, from the accelerated beamlets, the non-uniformity of the extracted current. For the complete characterization of the beam optics in the phase space, the design and prototyping of many "beamlet plugs" was carried out to allow the isolation of a few beamlets by closing surrounding apertures of the plasma grid: with this configuration, to be applied only to a limited number of beamlets, it will be possible to continue the single-beamlet optics study via IR calorimetry and the emittance scanner [14], for the optimization -2 -…”
Section: Jinst 18 C09001 2 Measurement Of the Beam Currentmentioning