2024
DOI: 10.1016/j.prosdent.2022.07.006
|View full text |Cite
|
Sign up to set email alerts
|

Fit and retention of complete denture bases: Part I – Conventional versus CAD-CAM methods: A clinical controlled crossover study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(21 citation statements)
references
References 31 publications
0
21
0
Order By: Relevance
“…Improved denture base fit was also reported with PEEK denture base material 50 . On the contrary, others found that the retention and fit of the complete denture bases manufactured using CAD/CAM techniques were comparable to that of conventionally manufactured bases 51 …”
Section: Discussionmentioning
confidence: 84%
See 1 more Smart Citation
“…Improved denture base fit was also reported with PEEK denture base material 50 . On the contrary, others found that the retention and fit of the complete denture bases manufactured using CAD/CAM techniques were comparable to that of conventionally manufactured bases 51 …”
Section: Discussionmentioning
confidence: 84%
“…50 On the contrary, others found that the retention and fit of the complete denture bases manufactured using CAD/CAM techniques were comparable to that of conventionally manufactured bases. 51 The volumetric differences related to conventional denture base processing are no longer a problem because it is not present in case of CAD/CAM. As a result, when CAD/CAM-manufactured dentures were compared with conventional dentures, the fitting surface of the CAD/CAM fabricated dentures revealed a higher similarity to the master cast surface and provided more accurate and reproducible denture fabrication technique.…”
Section: Discussionmentioning
confidence: 99%
“…The characteristics of the participant have been reported previously. 19 The results comparison indicates higher clinical retention forces of the bases from a conventional impression compared with those manufactured from a digital scan at all 3 testing locations, namely the post dam and the right and left tuberosities (Table 1). Table 2 reports on the comparison of clinical retention after 2 weeks of storage in artificial saliva, where the conventional impression generated higher clinical retention of the corresponding bases.…”
Section: Resultsmentioning
confidence: 94%
“…The details of the manufacturing methods and materials used, as well as the platform design, have been reported previously. 19 The denture bases were sprayed with an antiglare scanning spray (Helling 3D Scan Spray; Helling GmbH) and scanned with a calibrated laboratory scanner (Iscan D103i; Imetric 3D SA). 20 Data from the scans were stored in a standard tessellation language (STL) format.…”
Section: Methodsmentioning
confidence: 99%
“…In-vitro and in-vivo testing often provide different results, so understanding if this difference is of clinical significance is important. The first to clinically evaluate conventional, milled and printed denture retention were Maniewicz et al, 25 who found similar retention and fit of milled and printed maxillary dentures when compared to conventionally processed dentures. Thus, the differences in denture base adaptation found in the lab are likely not of clinical significance.…”
Section: Denture Base Adaptationmentioning
confidence: 99%