Five-year Experience with Crossfire?? Highly Cross-linked Polyethylene

Abstract: Therapeutic study, Level III (retrospective comparative study). See the Guidelines for Authors for a complete description of levels of evidence.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
64
0
3

Year Published

2008
2008
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 147 publications
(72 citation statements)
references
References 26 publications
5
64
0
3
Order By: Relevance
“…We found the early wear rates of this HCLPE in a young patient population are comparable to published data for older populations [10,28]. In addition, the polyethylene wear rate that we determined was less than that of previously reported conventional polyethylene historic controls [10, 24-26, 28, 39].…”
Section: Discussionsupporting
confidence: 73%
See 1 more Smart Citation
“…We found the early wear rates of this HCLPE in a young patient population are comparable to published data for older populations [10,28]. In addition, the polyethylene wear rate that we determined was less than that of previously reported conventional polyethylene historic controls [10, 24-26, 28, 39].…”
Section: Discussionsupporting
confidence: 73%
“…Durasul 1 is manufactured by electron beam radiation with 9.5 Mrad at 120°C; it then is remelted at 150°C and stored in ethylene oxide. The calculated annual wear for Crossfire TM (Stryker, Kalamazoo, MI) HCLPE in a study with an average followup of 5 years was 0.036 mm per year with a mean patient age of 57 years [10]. In our series, the wear rate was 0.026 mm per year ± 0.135 at a mean of 4.0 years followup.…”
Section: Discussionmentioning
confidence: 47%
“…For annealed and gamma inert sterilized highly crosslinked components, in vivo oxidation occurs preferentially at the rim of the liner, which has the greatest exposure to oxygen-containing body fluids and tissues [17]. Previous studies have reported lower oxidation of the bearing surface for annealed and gamma inert sterilized highly crosslinked liners [7,18] as compared with the rim and may explain the general preservation of wear properties seen in clinical studies [9,18,28]. However, in the case of a malfunctioning hip such as chronic instability with dislocation, rim oxidation may contribute to localized delamination or rim fracture [18].…”
Section: Introductionmentioning
confidence: 99%
“…However, studies reporting on the midterm (C 5 years average followup) in vivo performance of these PE liners are scant [1,4,7,9,37]. Such studies are of utmost importance because radiographic osteolysis is a phenomenon rarely seen before 5 years of followup.…”
Section: Introductionmentioning
confidence: 99%