2021
DOI: 10.1016/j.aca.2021.338399
|View full text |Cite
|
Sign up to set email alerts
|

Five years of innovations in development of glow discharges generated in contact with liquids for spectrochemical elemental analysis by optical emission spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
37
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 35 publications
(38 citation statements)
references
References 60 publications
1
37
0
Order By: Relevance
“…For other APGD systems, an increase in the sample acidity usually led to the enhancement of the analytical signals of the studied elements and the deterioration of the discharge stability. 1,6 However, it should be pointed out that in this case, when the discharge was operated in contact with owing solutions, the concentration of HNO 3 or HCl in solutions was not higher than 0.1 mol L À1 . In the present system, where HDC-APGD was used and operated in contact with a solution drop, its impaired stability was observed when the HNO 3 concentration exceeded 0.6 mol L À1 , which indicates an increased tolerance to this acid.…”
Section: The Optimization By the Design Of Experiments Approachmentioning
confidence: 78%
See 2 more Smart Citations
“…For other APGD systems, an increase in the sample acidity usually led to the enhancement of the analytical signals of the studied elements and the deterioration of the discharge stability. 1,6 However, it should be pointed out that in this case, when the discharge was operated in contact with owing solutions, the concentration of HNO 3 or HCl in solutions was not higher than 0.1 mol L À1 . In the present system, where HDC-APGD was used and operated in contact with a solution drop, its impaired stability was observed when the HNO 3 concentration exceeded 0.6 mol L À1 , which indicates an increased tolerance to this acid.…”
Section: The Optimization By the Design Of Experiments Approachmentioning
confidence: 78%
“…It was established that in most cases, the evaluated enhancement factors are in good agreement with those reported in the literature. 1,5,9 The greatest improvement of the analyte responses was obtained in the cases of formic acid, i.e., $2.4-2.6-fold for Ag, Cd, Hg and Pb and formaldehyde, i.e., $1.2-1.4-fold for Mg, Mn and Tl. Due to the better stability of the HDC-APGD system and considering the high enhancement factors, formic acid (8%, m/ m) was used in the analysis of the CRM.…”
Section: The Effect Of the Addition Of Aiding Substancesmentioning
confidence: 97%
See 1 more Smart Citation
“…Generally, the composition and excitation power of microplasma are determined by the discharge gas, sample solution, electrode polarity, and construction of discharge cells. 13,28 For example, flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) is favorable for the determination of a group of elements, including Ag, Bi, Cd, Hg, In, Pb, Tl, and Zn. 28,29 Up to now, only the vapor generation of Hg, Os, and I could be obtained by using pure He/Ar microplasma.…”
mentioning
confidence: 99%
“…13,28 For example, flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) is favorable for the determination of a group of elements, including Ag, Bi, Cd, Hg, In, Pb, Tl, and Zn. 28,29 Up to now, only the vapor generation of Hg, Os, and I could be obtained by using pure He/Ar microplasma. 15,22,23 Hydrogen is required for the μPIVG of Cd and Zn while remarkably suppressing the μPIVG of Hg.…”
mentioning
confidence: 99%