1987
DOI: 10.3109/17453678709146468
|View full text |Cite
|
Sign up to set email alerts
|

Fixation of displaced femoral neck fractures: A comparison between sliding screw plate and four cancellous bone screws

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
49
1
2

Year Published

1990
1990
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 106 publications
(58 citation statements)
references
References 29 publications
6
49
1
2
Order By: Relevance
“…It was also reported by Swiontkowski and Winquist [37] that use of cannulated screws for femoral neck fractures causes lower blood loss during operation. Madsen et al [38] reported that application of DHS for these fractures causes prolonged operation and more blood loss, which supports the results of our study. In our study, there was no difference between groups according to occurrence of AVN (p>0.05), and this complication was seen more in displaced fractures in both groups (p>0.05).…”
Section: Discussionsupporting
confidence: 83%
“…It was also reported by Swiontkowski and Winquist [37] that use of cannulated screws for femoral neck fractures causes lower blood loss during operation. Madsen et al [38] reported that application of DHS for these fractures causes prolonged operation and more blood loss, which supports the results of our study. In our study, there was no difference between groups according to occurrence of AVN (p>0.05), and this complication was seen more in displaced fractures in both groups (p>0.05).…”
Section: Discussionsupporting
confidence: 83%
“…The results with the SGN compare favourably with those of previous reports on the SHS 3,4,[7][8][9]31 and are comparable with those previously reported with the MSP. 4,9-11 The main problem remains the risk of intra-operative fractures, 3/109 (2.75%) in our study, although, in most cases, they were induced by inappropriate surgical technique.…”
Section: Discussionsupporting
confidence: 82%
“…Many studies have found small or no significant differences when comparing methods of internal fixation (Nordkild et al 1985, Svenningsen et al 1985, Paus et al 1986, Madsen et al 1987. Others have shown that the outcome can be influenced by the choice of the internal fixation device Andersen 198 1, Frandsen et al 1984, Svenningsen et al 1984).…”
Section: Internal Fixation Of 41 0 Cervical Hip Fractures a Randomizementioning
confidence: 99%