2019
DOI: 10.1049/iet-pel.2018.5395
|View full text |Cite
|
Sign up to set email alerts
|

Fixed switching frequency predictive control of an asymmetric source dual inverter system with a floating bridge for multilevel operation

Abstract: This study proposes a modified modulated model predictive control (MMPC) scheme to control an open-end winding induction motor drive using an asymmetric source dual inverter with one floating bridge. The control algorithm uses a modulation algorithm within the cost function optimisation scheme to avoid variable switching frequency. The voltage of the floating capacitor is regulated utilising predefined redundant switching sequences as well as the voltage vector location is identified to improve calculation tim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…Two different speed references are considered, which result in as many modulation indexes (M.I. ), as defined in (5). From Fig.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two different speed references are considered, which result in as many modulation indexes (M.I. ), as defined in (5). From Fig.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…According to their power supply arrangement, the dual converters generally feature three different configurations, which are dual converters with 1) isolated supplies, 2) one common source and 3) a floating bridge [1], [5]. The dual converter using a common voltage source requires to eliminate the zero-sequence current, while the dual converter with a floating bridge demands to regulate the capacitor voltage at the desired value.…”
Section: Introductionmentioning
confidence: 99%
“…This is because the switching pattern that has to be generated is re‐calculated after each sampling time. However, recent progress in computational capabilities has overcome this setback and has thus, paved the way to make the best use of this control strategy [17–24].…”
Section: Introductionmentioning
confidence: 99%
“…Regarding the dual converter with FC, one of research hotspots is investigating the suitable approach to enhance the voltage utilization of DC-link [4]- [7]. This is extremely critical for the motor drive applications [8].…”
Section: Introductionmentioning
confidence: 99%
“…For instance, an MPC technique for dual converters is described in [5] and an enhanced technique with fixed switching frequency is proposed in [7]. However, the voltage utilization of DC-link by MPC has not been considered in the previous paper.…”
Section: Introductionmentioning
confidence: 99%