2021
DOI: 10.1016/j.snb.2021.130263
|View full text |Cite
|
Sign up to set email alerts
|

Flexible copper-biopolymer nanocomposite sensors for trace level lead detection in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 41 publications
(14 citation statements)
references
References 55 publications
0
12
0
Order By: Relevance
“…The linear regression equation between current difference (ΔI p ) and the concentration of • OH was ΔI p (μA) = 0.300[ • OH] − 0.0429 (R 2 = 0.9933), ΔI p = I 0 − I p , I 0 and I p were the peak currents of MB obtained from electrodes before and after incubated with various concentration of • OH ( Figure 4 D). The limit of detection was estimated from the equation: LOD = 3σ/K, σ was the standard deviation of the blank solution (i.e., without • OH), and K was the slope of the calibration graph [ 43 ]. Thus, ΔI p became larger for decreasing MB values.…”
Section: Resultsmentioning
confidence: 99%
“…The linear regression equation between current difference (ΔI p ) and the concentration of • OH was ΔI p (μA) = 0.300[ • OH] − 0.0429 (R 2 = 0.9933), ΔI p = I 0 − I p , I 0 and I p were the peak currents of MB obtained from electrodes before and after incubated with various concentration of • OH ( Figure 4 D). The limit of detection was estimated from the equation: LOD = 3σ/K, σ was the standard deviation of the blank solution (i.e., without • OH), and K was the slope of the calibration graph [ 43 ]. Thus, ΔI p became larger for decreasing MB values.…”
Section: Resultsmentioning
confidence: 99%
“…For successful biosensing activity, selecting an appropriate working electrode is essential. Recently, several works have focused on the development and modification of different electrode materials made from carbon elements, 46 copper, 47 gold, 48 platinum, 49 iron, 50 cobalt, 51 nickel, among others 52 to improve the stability, selectivity, and sensitivity of the sensors. Furthermore, the miniaturisation of working electrodes has opened a promising path for developing small-sized sensors like the screen-printed electrode-based biosensing devices that need a minimal sample amount for sensing.…”
Section: Types Of Sensors For Food Biomarker Detectionmentioning
confidence: 99%
“…24,25 The screen-printed based sensors are of vital importance that can fulfill the demand for miniaturization, sensitivity, and selectivity in biological, water, food, and drug analysis. 26–29…”
Section: Introductionmentioning