2011
DOI: 10.1784/insi.2011.53.6.316
|View full text |Cite
|
Sign up to set email alerts
|

Flexible ultrasonic transducer arrays for health monitoring of an aircraft component

Abstract: 2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2013
2013
2013
2013

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…, 4 mm pitch) on 75 μm thick Ti foil. The fabrication of the FUT array consists of six main steps [7,9]: (1) preparation of a high dielectric constant lead-zirconate-titanate (PZT) solution [8], (2) ball milling of the piezoelectric PZT powders in a PZT solution to submicron sizes, (3) sensor spraying using slurries to produce a film with thickness of 5 to 20 μm, (4) heat treatment to produce a solid PZT composite (PZT-c) thick film, (5) Corona poling to obtain piezoelectricity, and (6) colloidal silver spraying with a mask to deposit the top electrodes and electrically conducting lines. Steps (3,4) are performed multiple times to produce an optimal PZT-c film thickness for the specified ultrasonic operating frequency (center frequency).…”
Section: Fabrication Of Piezoelectric 1d Fut Arraymentioning
confidence: 99%
See 2 more Smart Citations
“…, 4 mm pitch) on 75 μm thick Ti foil. The fabrication of the FUT array consists of six main steps [7,9]: (1) preparation of a high dielectric constant lead-zirconate-titanate (PZT) solution [8], (2) ball milling of the piezoelectric PZT powders in a PZT solution to submicron sizes, (3) sensor spraying using slurries to produce a film with thickness of 5 to 20 μm, (4) heat treatment to produce a solid PZT composite (PZT-c) thick film, (5) Corona poling to obtain piezoelectricity, and (6) colloidal silver spraying with a mask to deposit the top electrodes and electrically conducting lines. Steps (3,4) are performed multiple times to produce an optimal PZT-c film thickness for the specified ultrasonic operating frequency (center frequency).…”
Section: Fabrication Of Piezoelectric 1d Fut Arraymentioning
confidence: 99%
“…It is noted that the signal strength of the FUTs made on Ti foil is normally a few dB better than that achieved from FUTs made on SS foil because of a decrease in substrate oxidation during heat treatment. However, FUTs using SS foils may be brazed onto steel substrates such as pipes for SHM purposes at HT [9]. Finally another insulation layer acting as a protection layer to prevent moisture, which may also sustain temperatures of up to 150 °C was coated, but not shown in Figure 1.…”
Section: Fabrication Of Piezoelectric 1d Fut Arraymentioning
confidence: 99%