FlexPES: a versatile soft X-ray beamline at MAX IV Laboratory

Abstract: FlexPES is a soft X-ray beamline on the 1.5 GeV storage ring at MAX IV Laboratory, Sweden, providing horizontally polarized radiation in the 40–1500 eV photon energy range and specializing in high-resolution photoelectron spectroscopy, fast X-ray absorption spectroscopy and electron–ion/ion–ion coincidence techniques. The beamline is split into two branches currently serving three endstations, with a possibility of adding a fourth station at a free port. The refocusing optics provides two focal points on each … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 11 publications
0
23
0
Order By: Relevance
“…Up to 200 L of O 2 , a shift by 0.1 eV is observed in the O 1s binding energy, while from 200 to 300 L it additionally shifts by 0.1 eV, remaining then nearly constant for even higher O 2 exposures. For resolving this small energy shift, high resolution at FlexPES is mandatory. More bulk-sensitive O 1s spectra are shown in Figure S7b.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Up to 200 L of O 2 , a shift by 0.1 eV is observed in the O 1s binding energy, while from 200 to 300 L it additionally shifts by 0.1 eV, remaining then nearly constant for even higher O 2 exposures. For resolving this small energy shift, high resolution at FlexPES is mandatory. More bulk-sensitive O 1s spectra are shown in Figure S7b.…”
Section: Resultsmentioning
confidence: 99%
“…16−20 The film thickness of stoichiometric CeO 2 (111) is determined by X-ray reflectometry (XRR, PANalytical X'Pert PRO MRD) to be 5.6 nm, corresponding to 18 O−Ce−O trilayers. 10 The stoichiometric CeO 2 (111)-Ru(0001) samples (prepared in the homelab at the JLU) are subsequently transferred to the preparation chamber of the permanent endstation EA01 (Surface and Material Science branch) at the FlexPES beamline 21 at MAX IV in Lund, Sweden. On-site, the CeO 2 (111)-Ru(0001) sample is annealed for t = 15 min in p(O 2 ) = 10 −6 mbar, followed by a quick annealing step to T = 1200 K in p(O 2 ) = 10 −6 mbar to remove potential carbon contamination during the sample transfer.…”
Section: Experimental and Theoretical Detailsmentioning
confidence: 99%
See 1 more Smart Citation
“…Photoelectron Spectroscopy Measurements and Analysis. PES measurements were carried out at the FlexPES beamline 32 at the MAX IV facility and at the CoESCA endstation at the BESSY II electron storage ring. 33 At FlexPES, the X-rays were generated by a linearly polarized undulator with a period length of 54.4 mm and monochromated using a plane grating monochromator (modified Zeiss SX700).…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…The XPS measurements were performed at the Surface Materials Science branch of the FlexPES beamline at the MAX IV synchrotron . This beamline is dedicated to high-resolution XPS and soft-wavelength X-ray absorption measurements.…”
Section: Experimental and Computational Methodsmentioning
confidence: 99%