2015
DOI: 10.1155/2015/204861
|View full text |Cite
|
Sign up to set email alerts
|

Flexural Strength of Carbon Fiber Reinforced Polymer Repaired Cracked Rectangular Hollow Section Steel Beams

Abstract: The flexural behavior of rectangular hollow section (RHS) steel beams with initial crack strengthened externally with carbon fiber reinforced polymer (CFRP) plates was studied. Eight specimens were tested under three-point loading to failure. The experimental program included three beams as control specimens and five beams strengthened with CFRP plates with or without prestressing. The load deflection curves were graphed and failure patterns were observed. The yield loads and ultimate loads with or without rep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 17 publications
0
8
0
Order By: Relevance
“…Carbon fiber outer cladding structure is shown in Figure 12, where θ i indicates the lay angle. e function of this type structure is similar to that of I-beam [8]. e upper and lower horizontal layers are similar to the webs of I-beams, which is to increase the bending strength and shear strength of the whole structure.…”
Section: Improvement Of the Layer Structure Of The Carbon Fiber Closed Fixturementioning
confidence: 59%
See 1 more Smart Citation
“…Carbon fiber outer cladding structure is shown in Figure 12, where θ i indicates the lay angle. e function of this type structure is similar to that of I-beam [8]. e upper and lower horizontal layers are similar to the webs of I-beams, which is to increase the bending strength and shear strength of the whole structure.…”
Section: Improvement Of the Layer Structure Of The Carbon Fiber Closed Fixturementioning
confidence: 59%
“…erefore, in order to meet the mechanical performance requirements, carbon fiber laminate structures need to be elaborated. A quasi-isotropic pavement structure with 0°, ±45°, and 90°cross-arrangement is proposed to meet the mechanical performance requirements of some bent and sheared parts [8][9][10][11]. And to reduce the weight and improve the flexural rigidity and the stability, a carbon fiber foam sandwich structure is discussed in the aerospace [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Its failure was ductile limited to CFRP debonding and experienced the highest amount of concrete crushing at its midspan in this group (see Figure 14 ). In the past, sudden deboning of CFRP from the RS beams has been also reported in many studies [ 26 , 29 ].…”
Section: Resultsmentioning
confidence: 99%
“…Chen et al [ 29 ] carried out investigations on the influence of CFRP plates in restoring structural properties of rectangular hollow beams. They tested eight beams under 3-point loading out of which three beams were kept as controlled and five beams strengthened with CFRP plates with and without prestressing.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, the externally bonded strengthening technique is effective for enhancing the performance of steel structures. It has been convincingly proven that this technique is able to increase: the compression capacity of short steel members [ 11 , 12 , 13 ], flexural capacity of steel beams [ 14 , 15 , 16 , 17 , 18 ], torsional capacity of steel members [ 19 , 20 ], load bearing capacity of steel shear wall [ 21 , 22 , 23 ], tensile capacity of steel plates [ 24 , 25 , 26 , 27 , 28 ], and also buckling capacity of long steel columns [ 29 , 30 , 31 ]. However, this strengthening technique is considered to have drawbacks.…”
Section: Introductionmentioning
confidence: 99%