2016
DOI: 10.1016/j.prosdent.2015.06.022
|View full text |Cite
|
Sign up to set email alerts
|

Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
25
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(32 citation statements)
references
References 20 publications
6
25
0
1
Order By: Relevance
“…The latter contributes to the propagation of the existing flaws created by the sharp milling or post‐milling disc separation, leading to fracture at relatively moderate loads. These findings are in agreement with previous studies, which concluded that three‐unit FDPs fail at lower load to fracture if they are shaped with a sharp connector design compared to round symmetrical connector designs …”
Section: Discussionsupporting
confidence: 93%
“…The latter contributes to the propagation of the existing flaws created by the sharp milling or post‐milling disc separation, leading to fracture at relatively moderate loads. These findings are in agreement with previous studies, which concluded that three‐unit FDPs fail at lower load to fracture if they are shaped with a sharp connector design compared to round symmetrical connector designs …”
Section: Discussionsupporting
confidence: 93%
“…The present study compared the load to fracture of posterior FPDs under 2 conditions: no preloading and thermomechanical loading. Several authors have performed static load tests to study the load to fracture of ceramic materials and suggest that compressive testing is an adequate method . However, other authors recommend the use of artificial aging to reproduce oral environment conditions for in vitro studies of ceramic materials, as they may involve a decrease in fracture resistance.…”
Section: Discussionmentioning
confidence: 99%
“…Several authors have performed static load tests to study the load to fracture of ceramic materials and suggest that compressive testing is an adequate method. 1,9,27,28,31 However, other authors 3,10,12,19,[22][23][24]29,[32][33][34][35][36][37][38][39] recommend the use of artificial aging to reproduce oral environment conditions for in vitro studies of ceramic materials, as they may involve a decrease in fracture resistance. Nevertheless, fewer studies comparing static loading with some type of artificial aging have been reported, 7,19,23,24,34,35,[38][39][40] and the results are controversial.…”
Section: Discussionmentioning
confidence: 99%
“…The connector dimensions were 4x4 mm 2 with rounded broader radius of curvature (0.6mm) at the gingival area to enhance fracture resistance of the restoration according to multiple studies (30,31,38) .…”
Section: Discussionmentioning
confidence: 99%
“…Data were transferred to the computer connected to the milling machine to start designing. The fully anatomical IRFPD design was formed according to the manufacturer's directions and software recommendations including; 30 mm die spacer, modified ridge-lap pontic and 4x4 mm 2 connector dimensions with rounded 0.6mm radius of curvature at the gingival area (30,31) . Milling of wax patterns was then activated.…”
Section: Construction Of 20 Cad/cam Wax Patternsmentioning
confidence: 99%