2006
DOI: 10.1016/j.buildenv.2005.05.029
|View full text |Cite
|
Sign up to set email alerts
|

Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 65 publications
(35 citation statements)
references
References 11 publications
0
35
0
Order By: Relevance
“…Debonding failure of NSM FRP is interfacial debonding at the FRP-epoxy interface [12]. The failure of NSM FRP structural elements may occur due to splitting of the epoxy cover, cracking of the concrete surrounding the groove and pullout of the FRP bars or combined failure [13][14][15][16][17][18][19][20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…Debonding failure of NSM FRP is interfacial debonding at the FRP-epoxy interface [12]. The failure of NSM FRP structural elements may occur due to splitting of the epoxy cover, cracking of the concrete surrounding the groove and pullout of the FRP bars or combined failure [13][14][15][16][17][18][19][20][21][22][23][24].…”
Section: Introductionmentioning
confidence: 99%
“…It was concluded that amongst the all CFRP strengthening techniques, the NSM with laminates at 45° was the most effective, not only in terms of increasing beam shear resistance but also in assuring larger deformation capacity at beam failure. Tang et al (2006) used NSM strengthening technique to increase the flexural load carrying capacity of lightweight RC beams. After an experimental study, it was observed that beams strengthened with NSM glass fibre reinforced polymer (GFRP) bars showed a significant increase in ultimate moment ranging from 23% to 53% over the corresponding beams without NSM GFRP bars.…”
Section: Introductionmentioning
confidence: 99%
“…The beams were painted white to make cracks easier to detect. cracks observed in SPS concretes were less wide and finer than in control concrete [13]. The slope of the load-deflection curves decreased after the first crack has occurred and the relationship was still approximately linear until the steel started yielding.…”
Section: Flexural Behaviourmentioning
confidence: 82%
“…Researchers [13] investigated the characterisations of structural behaviour of reinforced lightweight aggregate concrete beams made with polystyrene aggregate strengthened with near surface mounted (NSM) glass fibre reinforced polymer (GFRP) bars. The parameters examined in their investigation were type of concretes (Control and polystyrene concretes), type of reinforcing bars (GFRP and steel), and type of adhesives.…”
Section: Previous Workmentioning
confidence: 99%