2012
DOI: 10.1007/978-3-642-29268-2_3
|View full text |Cite
|
Sign up to set email alerts
|

Flow Cytometry on a Chip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2012
2012
2015
2015

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 44 publications
0
4
0
Order By: Relevance
“…7 However, many rural areas, for example in Sub-Saharan Africa, the region most affected by HIV, do not have access to CD4 counting as they often lack the necessary infrastructure to ship blood samples to central labs and get the result back to the patient. Accordingly, there have been large efforts over the last decade 8 to miniaturize flow cytometers [9][10][11][12][13] or to develop alternative portable tests that can be carried out with minimal training, 7,14 for example LabNow, 15 PIMA (Alere), 16 Daktari, [17][18][19] Zyomyx. 20 Earlier, we developed a single platform image cytometer 21 that simplified the instrumentation and provided very promising results, [22][23][24] but still required precision for the sample preparation, which frequently cannot be met in the field by less experienced operators.…”
Section: Introductionmentioning
confidence: 99%
“…7 However, many rural areas, for example in Sub-Saharan Africa, the region most affected by HIV, do not have access to CD4 counting as they often lack the necessary infrastructure to ship blood samples to central labs and get the result back to the patient. Accordingly, there have been large efforts over the last decade 8 to miniaturize flow cytometers [9][10][11][12][13] or to develop alternative portable tests that can be carried out with minimal training, 7,14 for example LabNow, 15 PIMA (Alere), 16 Daktari, [17][18][19] Zyomyx. 20 Earlier, we developed a single platform image cytometer 21 that simplified the instrumentation and provided very promising results, [22][23][24] but still required precision for the sample preparation, which frequently cannot be met in the field by less experienced operators.…”
Section: Introductionmentioning
confidence: 99%
“…Currently, our system detects only a single color for each droplet. However, as has been previously shown by other groups on cell-based detection systems, 25,48 multicolor detection can be integrated with masked systems. The data acquisition electronics, which currently fundamentally limits the overall throughput to 10 4 drops min −1 , could be further improved (~50×) to exploit the high bandwidth of microelectronics.…”
Section: Discussionmentioning
confidence: 93%
“…The size of flow cytometers has decreased significantly over time even when imaging capabilities such as digital microscopy on a cellphone [ 10 ] were incorporated to the systems. However, the complexity of their large optical trains, sensitivity, and power requirement has prevented them from being effectively used in harsh environments or portable point-of-care diagnostics [ 11 , 12 ].…”
Section: Introductionmentioning
confidence: 99%
“…A handheld prototype of a flow cytometer which uses a PIN photodiode rather than a PMT is reported by Kiesel et al [ 12 ]. However the detection limit was about 200 molecules of equivalent phycoerythrin for 2 μm Rainbow calibration beads.…”
Section: Introductionmentioning
confidence: 99%