1985
DOI: 10.1007/bf00490916
|View full text |Cite
|
Sign up to set email alerts
|

Flow injection analysis of chloride in tap and sewage water using ion-selective electrode detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

1995
1995
2011
2011

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(20 citation statements)
references
References 7 publications
0
20
0
Order By: Relevance
“…This may be attributed to the different methods applied in determining the selectivity coefficient values in both batch and FI techniques, i.e. the matched potential and separate solution methods respectively [38][39][40]. This is interpreted by difference in times of interaction of interferents with the sensor in comparison to the main sensed ion; also the interference process is highly dependent on the rate of diffusion and the exchange reaction of the interfering ion [41].…”
Section: Selectivitymentioning
confidence: 94%
“…This may be attributed to the different methods applied in determining the selectivity coefficient values in both batch and FI techniques, i.e. the matched potential and separate solution methods respectively [38][39][40]. This is interpreted by difference in times of interaction of interferents with the sensor in comparison to the main sensed ion; also the interference process is highly dependent on the rate of diffusion and the exchange reaction of the interfering ion [41].…”
Section: Selectivitymentioning
confidence: 94%
“…Improved selectivity differs a bit from that inherent to the flow-injection mode of operation and is due only to the difference in time response of the primary and interfering ion. Improved selectivity is commonly observed with all ISEs [39]. The dominating contribution of the optimized membrane composition, manifested in improved membrane dynamic and surface properties, over that of the FI manifold and the beneficial sensor/ FI manifold interaction for achieving improved selectivity is emphasized.…”
Section: Selectivitymentioning
confidence: 97%
“…[30][31][32][33] This is interpreted by the difference in the time of the interaction of the interferents with the membrane surface. This difference increases with an increase in the interaction of the interferent with the membrane compared with the main sensed ion; also, the interference process is highly dependent on the rate of diffusion and the exchange reaction of the interfering ion.…”
Section: Selectivitymentioning
confidence: 99%