2018
DOI: 10.2116/analsci.17p571
|View full text |Cite
|
Sign up to set email alerts
|

Flow-Injection Chemiluminescence Method for Sensitive Determination of Ascorbic Acid in Fruit Juices and Pharmaceutical Samples Using a Luminol-Cetyltrimethylammonium Chloride Reversed Micelle System

Abstract: A highly sensitive flow-injection (FI) method was developed for the determination of ascorbic acid using chemiluminescence (CL) based detection. This method involved the following processes: (1) reduction of tetrachloroaurate(III) in hydrochloric acid with ascorbic acid; (2) on-line extraction of the residual Au(III) with rhodamine B from the aqueous hydrochloric acid solution into toluene, followed by the separation of the Au(III)-containing organic phase from the aqueous phase through a microporous Teflon me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…19,20 Flow injection analysis (FIA) methods have the advantages of higher reproducibility, higher sample throughput, lower reagent consumption, and easier procedures than the batchwise methods. [31][32][33][34][35][36] Several FIA systems based on optode detectors have been reported. [21][22][23][24][25][26][27][28] Therefore, the combination of an FIA system and the optode detector based on L-RB is considered to be a very effective analytical method for determining AS.…”
Section: Introductionmentioning
confidence: 99%
“…19,20 Flow injection analysis (FIA) methods have the advantages of higher reproducibility, higher sample throughput, lower reagent consumption, and easier procedures than the batchwise methods. [31][32][33][34][35][36] Several FIA systems based on optode detectors have been reported. [21][22][23][24][25][26][27][28] Therefore, the combination of an FIA system and the optode detector based on L-RB is considered to be a very effective analytical method for determining AS.…”
Section: Introductionmentioning
confidence: 99%
“…[17][18][19] CL detection methods are famous for their high sensitivity and wide dynamic linear ranges. [20][21][22][23] Nowadays, researchers are interested in using nanomaterials with unique properties to improve the CL systems. 20,21,24 Nanomaterials can play the role of emitters, catalysts or energy acceptors, improving the CL reactions and resulting in an enhanced emission.…”
Section: Introductionmentioning
confidence: 99%
“…This technique is accompanied by several advantages, including high sensitivity and sample throughput, controllable emission rate and safety. 28 Numerous analytical applications of flow injection (FI) techniques with CL detection have been reported for the determination of environmentally, pharmaceutically and biologically important analytes [29][30][31][32] using a number of oxidants. 33,34 Potassium permanganate (KMnO4) as a CL reagent has been extensively used since 1975, when sulfur dioxide (SO2) was determined in atmospheric samples by developing an analytical method in which KMnO4 was employed as a CL reagent.…”
Section: Introductionmentioning
confidence: 99%