Flow-injection on-line sorption preconcentration in a knotted reactor for electrothermal atomic absorption spectrometric determination of ultratrace amounts of cobalt in natural waters

Abstract: A flow-injection on-line sorption preconcentration-electrothermal atomic absorption spectrometric (ETAAS) method has been developed for the deter-

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1998
1998
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…A FI-ETAAS method was developed for the determination of ultra-trace amounts of cobalt in natural waters. [22] The preconcentration was achieved by online complexation of cobalt with APDC and subsequent sorption of the complex onto the inner walls of a KR. In this work, in order to reduce the eluate volume and to minimize dispersion, an air flow was used to drive the eluent for the elution of the adsorbed analyte and dispel the eluate into the graphite tube.…”
Section: Ammonium Pyrrolidine Dithiocarbamatementioning
confidence: 99%
“…A FI-ETAAS method was developed for the determination of ultra-trace amounts of cobalt in natural waters. [22] The preconcentration was achieved by online complexation of cobalt with APDC and subsequent sorption of the complex onto the inner walls of a KR. In this work, in order to reduce the eluate volume and to minimize dispersion, an air flow was used to drive the eluent for the elution of the adsorbed analyte and dispel the eluate into the graphite tube.…”
Section: Ammonium Pyrrolidine Dithiocarbamatementioning
confidence: 99%
“…Tao and Fang (110) incorporated a novel gravity phase separator into a FI-ETAAS system which was used for on-line solvent extraction preconcentration of Ni. Adams and co-workers used FI-ETAAS for the on-line separation and preconcentration of Sb (111), Tl (112), Pb (113), and Co (114). In each case, the analyte was chelated and sorbed on the inner wall of a knotted PTFE reactor.…”
Section: Electrothermal Atomizationmentioning
confidence: 99%
“…Up to now, various SPE sorbents have been employed for the preconcentration and determination of cobalt both in batch and FI modes. Some of these sorbents include C-18 bonded silica, 9-12 activated carbon, [13][14][15][16] functionalized cellulose, 17,18 knotted reactor, [19][20][21][22] modified alumina, [23][24][25][26] silica gel modified with glycerol, 27 and C-60 fullerene. 12 Among these solid phase sorbents, a good alternative to achieve very versatile systems that can be applied to a wide range of samples is the use of polymeric solid supports functionalized with complexing reagents.…”
Section: Introductionmentioning
confidence: 99%