2011
DOI: 10.1016/j.proci.2010.06.092
|View full text |Cite
|
Sign up to set email alerts
|

Flow structures in a lean-premixed swirl-stabilized combustor with microjet air injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 36 publications
(23 citation statements)
references
References 13 publications
0
23
0
Order By: Relevance
“…As the dilution levels were increased from χ CO2 = 0.63 (T ad = 2100 K) to χ CO2 = 0.67 (T ad = 1970 K), the flame lengths increase commensurate with what is expected for decreasing flame temperatures. The flame dynamics are controlled by the fluid-mechanics of the inner recirculation zone as was reported in our previous work on propane-air mixtures [15]. The next abrupt transition is seen at χ CO2 = 0.67 (T ad = 1970 K) where the instability jumps from the three-quarter wave mode to the quarter wave mode with a slightly lower limit-cycle amplitude.…”
Section: B Dynamic Characteristics Of Oxy-fuel Mixturesmentioning
confidence: 56%
See 1 more Smart Citation
“…As the dilution levels were increased from χ CO2 = 0.63 (T ad = 2100 K) to χ CO2 = 0.67 (T ad = 1970 K), the flame lengths increase commensurate with what is expected for decreasing flame temperatures. The flame dynamics are controlled by the fluid-mechanics of the inner recirculation zone as was reported in our previous work on propane-air mixtures [15]. The next abrupt transition is seen at χ CO2 = 0.67 (T ad = 1970 K) where the instability jumps from the three-quarter wave mode to the quarter wave mode with a slightly lower limit-cycle amplitude.…”
Section: B Dynamic Characteristics Of Oxy-fuel Mixturesmentioning
confidence: 56%
“…Premixed CH 4 /O 2 /CO 2 or premixed CH 4 /air enters the combustor through a 38 mm diameter inlet pipe. The swirler is located 5 cm upstream of the expansion plane and has 8 blades with an estimated swirl number of 0.7 [15]. From the expansion plane downstream, the inner diameter is 76 mm.…”
Section: Methodsmentioning
confidence: 99%
“…The combustor discharges into a plenum at near atmospheric pressure. The experimental setup is similar to the ones previously investigated by our research group [15][16][17][18]. The swirl number is fixed and estimated at S $ 0.7 based on the swirler's vanes angle, the Reynolds number based on the inlet diameter is Re Din ¼ 20; 000, and the pressure is atmospheric.…”
Section: Introductionmentioning
confidence: 99%
“…All frequencies are filtered except for the one related to the subharmonic frequency of instability, in order to isolate the coherent structure associated explicitly with the timescale of interest. Details of the DMD algorithm can be found in [37] and an application on a gas turbine combustor can be found in [38] and in [12]. The results of the reconstruction show an azimuthally convected high heat release rate region.…”
Section: Casementioning
confidence: 99%