2021
DOI: 10.1016/bs.ctm.2021.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence-based sensing of the bioenergetic and physicochemical status of the cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
3
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 236 publications
0
8
0
Order By: Relevance
“…3B, bottom); for accurate estimates of the mobility of a particle with a D sim value of 10 m 2 /s, a t value of around 10 s would be required, especially for the analysis of regions close to the cell boundaries. Reduction of t value to the submillisecond time scale is not possible with conventional light microscopy cameras, given the brightness and photostability of photoactivatable fluorescent proteins, and the background fluorescence of the biological samples (32,(38)(39)(40). However, given the linear dependence of D on t, any reduction in acquisition time would improve the quality of the data in a predictable manner.…”
Section: Quantitative Implications Of Confinementmentioning
confidence: 99%
“…3B, bottom); for accurate estimates of the mobility of a particle with a D sim value of 10 m 2 /s, a t value of around 10 s would be required, especially for the analysis of regions close to the cell boundaries. Reduction of t value to the submillisecond time scale is not possible with conventional light microscopy cameras, given the brightness and photostability of photoactivatable fluorescent proteins, and the background fluorescence of the biological samples (32,(38)(39)(40). However, given the linear dependence of D on t, any reduction in acquisition time would improve the quality of the data in a predictable manner.…”
Section: Quantitative Implications Of Confinementmentioning
confidence: 99%
“…Control monocytes appear rounding with preserved subcellular organelles like mitochondria with well-organized cristae (Figure 2b,c). After Epsom salt exposure, swollen cells can be observed together with noticeable mitochondria bulge (Figure 2d,e), probably consequent of an osmotic alteration which rarely leads to necrotic death, confirming that osmotic shocking alone is relatively inefficient in cell disruption (Mantovanelli et al, 2021).…”
Section: Resultsmentioning
confidence: 61%
“…Some fluorescence biosensors rely on only one fluorescent probe with a specific emission wavelength, which makes the biosensors vulnerable to different factors such as the concentration of the probe and the external environment 86–88 . Therefore, the search for low‐cost, biocompatible fluorescent probes or the development of new combinations of fluorescent probes is the focus of future research.…”
Section: Colorimetric and Fluorescence Biosensingmentioning
confidence: 99%
“…as the concentration of the probe and the external environment. [86][87][88] Therefore, the search for low-cost, biocompatible fluorescent probes or the development of new combinations of fluorescent probes is the focus of future research. Cui et al displayed a wearable patch based on the ratiometric fluorescent nanohybrid, realizing non-invasive and visual monitoring of sweat glucose 89 (Figure 4C).…”
Section: F I G U R Ementioning
confidence: 99%