2005
DOI: 10.1021/ja0508976
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence Correlation Spectroscopy, a Tool to Investigate Supramolecular Dynamics:  Inclusion Complexes of Pyronines with Cyclodextrin

Abstract: The control of supramolecular systems requires a thorough understanding of their dynamics on a molecular level. We present fluorescence correlation spectroscopy (FCS) as a powerful spectroscopic tool to study supramolecular dynamics with single molecule sensitivity. The formation of a supramolecular complex between beta-cyclodextrin (beta-CD) as host and pyronines Y (PY) and B (PB) as guests is studied by FCS. Global target analysis of full correlation curves with a newly derived theoretical model yields in a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

9
195
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 124 publications
(212 citation statements)
references
References 58 publications
9
195
1
Order By: Relevance
“…[13,16,[22][23][24][25][26] Here we need a solution which describes two interconverting fluorescent species with different diffusion coefficients observed under Gaussian illumination. Under the further assumption that the relaxation time of the reaction is much shorter than the typical diffusion times of guest and complex (fast exchange), the correlation function shown by Equation (4) is obtained for diffusion and reaction: [27] …”
Section: Theorymentioning
confidence: 99%
See 3 more Smart Citations
“…[13,16,[22][23][24][25][26] Here we need a solution which describes two interconverting fluorescent species with different diffusion coefficients observed under Gaussian illumination. Under the further assumption that the relaxation time of the reaction is much shorter than the typical diffusion times of guest and complex (fast exchange), the correlation function shown by Equation (4) is obtained for diffusion and reaction: [27] …”
Section: Theorymentioning
confidence: 99%
“…[27] Briefly, the set-up comprises a continuous-wave argon ion laser for excitation at 515 nm (PY and PB) and 496.5 nm (R123), a confocal inverted microscope with high aperture objective (Olympus 60 , NA 1.20, water immersion), a pinhole of 100 mm diameter, single-photon avalanche photodiodes (SPCM-AQR-14, Perkin-Elmer Vaudreuil, Quebec, Canada), and TCSPCmodules (SPC 132, Becker & Hickl GmbH, Berlin, Germany). Correlation curves were calculated with a fast home-built LabVIEW routine (National Instruments).…”
Section: Theorymentioning
confidence: 99%
See 2 more Smart Citations
“…À was obtained through autocorrelation analysis using the following Equation (1) [43][44][45] ( Figure 2c). …”
Section: Angewandte Chemiementioning
confidence: 99%