2006
DOI: 10.1080/05704920600929498
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescence Spectroscopy of Biological Tissues—A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
74
1
6

Year Published

2007
2007
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 131 publications
(84 citation statements)
references
References 41 publications
3
74
1
6
Order By: Relevance
“…8 Light-induced autofluorescence spectroscopy with laser source can be used to detect and quantify differences between healthy tissue and pathological lesions in vivo, in real time, with easy-to-use methodology for measurements, lack of need for contrast agents, precision, selectivity, and specificity (Table 1). [11][12][13] The use of lasers, instead of incoherent light sources in autofluorescence spectroscopy, has the advantage of using an exact wavelength and can deliver the excitation light with fibers to the selected body site, without significant loss of light power, and derive, in real time, medical information from naturally occurring endogenous fluorophores, without adding external (exogenous) fluorescent markers.…”
Section: Lif: Basic Principles Made Simplementioning
confidence: 99%
“…8 Light-induced autofluorescence spectroscopy with laser source can be used to detect and quantify differences between healthy tissue and pathological lesions in vivo, in real time, with easy-to-use methodology for measurements, lack of need for contrast agents, precision, selectivity, and specificity (Table 1). [11][12][13] The use of lasers, instead of incoherent light sources in autofluorescence spectroscopy, has the advantage of using an exact wavelength and can deliver the excitation light with fibers to the selected body site, without significant loss of light power, and derive, in real time, medical information from naturally occurring endogenous fluorophores, without adding external (exogenous) fluorescent markers.…”
Section: Lif: Basic Principles Made Simplementioning
confidence: 99%
“…fluorescence microscopy ͉ time-resolved luminescence spectroscopy ͉ transition metal complexes ͉ cyclometalation U nderstanding chemical processes that underpin biological systems relies on technological and conceptual developments that permit noninvasive monitoring of biological processes in real time. Fluorescence microscopy is one of the most widely used tools in the biological sciences, benefiting from exquisite sensitivity, excellent spatial resolution, and unparalleled temporal resolution (1,2). It permits a breadth of investigations from interactions of single molecules to wholeorganism studies and relies on light emission from either endogenous fluorophores or external fluorescent probes to monitor the local environment and changes therein.…”
mentioning
confidence: 99%
“…При этом необходимо отметить, что тип дефекта в структуре гидроксиапатита кальция может определять положение максимума люми-несценции [13]. Кроме внутрицентровых дефектов, изме-нения в спектр ФЛ могут вносить различные фазовые превращения, происходящие при кариозных процессах в эмали и дентине зуба человека [14]. Очевидно, что в случае регистрации ФЛ от нативных тканей, которые уже были подвергнуты обработке или препарированию, необходимо наличие базы спектров ФЛ эталонов, кото-рые позволят выделить сигнал от возможных патоген-ных образований в зубной ткани, материала пломбы и здоровых участков интактной зубной ткани.…”
Section: Introductionunclassified
“…Однако при этом области твердой ткани зуба с патологией могут быть выявлены лишь на стадии " белого пятна" и позднее, что оставляет открытыми вопросы об интерпретации полезного сигнала, а так-же своевременной диагностике природы заболевания. Поэтому в последнее время активно разрабатываются и находят клиническое применение различные диагно-стические устройства, принцип действия которых ос-нован на оценке сигнала ФЛ от твердых тканей зу-ба [14,[17][18][19][20][21]. Обработанный программным комплексом ФЛ сигнал позволяет визуализировать картину пора-женной области.…”
Section: Introductionunclassified