2019
DOI: 10.1039/c9tc04567h
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent chemodosimeters for fluoride ionsviasilicon-fluorine chemistry: 20 years of progress

Abstract: Critical commentary on and a brief summary of representative F− fluorescent probes, imaging agents and nanosensors based on Si–F chemistry are provided, followed by pointing out the limitations of current systems and possible future directions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
33
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(34 citation statements)
references
References 99 publications
0
33
0
1
Order By: Relevance
“…inducing cleavage of an Si-O or Si-C bond (For a review, see: Chen et al, 2019. See also: Yamaguchi et al, 2000Descalzo et al, 2002;Kim and Swager, 2003;Zhu et al, 2005;Bozdemir et al, 2010;Hu et al, 2010;Lu et al, 2011;Baker and Phillips, 2012;Li et al, 2014;Turan and Akkaya, 2014;Zou et al, 2014;Chavali et al, 2015;Mahapatra et al, 2015;Gabrielli and Mancin, 2016;Chansaenpak et al, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…inducing cleavage of an Si-O or Si-C bond (For a review, see: Chen et al, 2019. See also: Yamaguchi et al, 2000Descalzo et al, 2002;Kim and Swager, 2003;Zhu et al, 2005;Bozdemir et al, 2010;Hu et al, 2010;Lu et al, 2011;Baker and Phillips, 2012;Li et al, 2014;Turan and Akkaya, 2014;Zou et al, 2014;Chavali et al, 2015;Mahapatra et al, 2015;Gabrielli and Mancin, 2016;Chansaenpak et al, 2018).…”
Section: Introductionmentioning
confidence: 99%
“…Synthesis of 2-(4,5-diphenyl-1-(4 0 -vinyl-[1,1 0 -biphenyl]-4-yl)-1Himidazol-2-yl)phenol (2) Under nitrogen, a biphasic solution of imidazole (1.00 g, 2.14 mmol), 4-styrene boronic acid (0.38 g, 2.57 mmol), sodium carbonate (0.68 g, 6.42 mmol) and [Pd(PPh 3 ) 4 ] (3 mol%) in tetrahydrofuran (THF) and water (20 : 8; 56 mL) was heated at reux for 12 hours. The organic layer was separated and the aqueous layer was extracted twice (20 mL) with ethyl acetate.…”
Section: Methodsmentioning
confidence: 99%
“… 32 34 However, for probes based on the first two mechanisms, they suffered from unsatisfactory selectivity or irreversibility. 35 37 35 37 Although desilylation-based probes for fluoride ion could overcome the above disadvantages, most of them could only need a high level of organic solvents or monitor tetrabutylammonium fluoride in organic solvents. Additionally, most of these reported had long reaction time or required cationic surfactant, cetyltrimethylammonium bromide (CTAB), to increase the reaction rate, which greatly restricted their practical application.…”
Section: Introductionmentioning
confidence: 99%