1956
DOI: 10.1021/ac60116a042
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent X-Ray Spectrographic Determination of Uranium in Waters and Brines

Abstract: In a search for a method sensitive to small concentrations of uranium in water and brine, a modification of a fluorometric method was adopted. The uranium is precipitated from the water or brine by the method of Smith and Grimaldi, and the ashed precipitate is analyzed by fluorescent x-ray spectrography. When an internal standard is required, yttrium nitrate is added. The sample holder of the Norelco x-ray spectrograph wTas modified to place the small precipitate samples in the most intense part of the beam fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

1957
1957
1972
1972

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…The application of x-ray fluorescence analysis to the determination of uranium in waters and brines was reported by Kehl and Russell (128). The uranium is concentrated by Grimaldi's technique using aluminum phosphate coprecipitation.…”
Section: Uranium Radium and Thoriummentioning
confidence: 99%
“…The application of x-ray fluorescence analysis to the determination of uranium in waters and brines was reported by Kehl and Russell (128). The uranium is concentrated by Grimaldi's technique using aluminum phosphate coprecipitation.…”
Section: Uranium Radium and Thoriummentioning
confidence: 99%
“…Yttrium (3,5, IS, IS), strontium (4, 10, 12, 13), and bromine (10,13) have been used in the analysis of either plutonium or uranium. The uranium-tothorium ratio has also been used (1,14), although in this case thorium was not added as an internal standard but was already present in the sample.…”
mentioning
confidence: 99%
“…Thus Pish and Huffman (5) first used the method to analyze uranium solutions directly, claiming an accuracy of 1% in the range studied by them (0.01 to l.OAf). Kehl and Russel (4), and also Flikkema, Larsen, and Schablaske (2), precipitated uranium from solution (U: 10_3M) and studied the precipitates by x-ray fluorescence. Wilson and Wheeler (9) studied the effect of using different x-ray targets when analyzing for uranium in solution, while more recently, Smithson,Eager,and Van Cleave (6) have applied the method for the direct determination of uranium in flotation concentrates and leach liquors.…”
mentioning
confidence: 99%