2019
DOI: 10.1039/c8ob02711k
|View full text |Cite
|
Sign up to set email alerts
|

Fluorogenic probes for super-resolution microscopy

Abstract: Fluorogenic probes efficiently reduce non-specific background signals, which often results in highly improved signal-to-noise ratios.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
95
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 114 publications
(95 citation statements)
references
References 121 publications
(102 reference statements)
0
95
0
Order By: Relevance
“…The uorogenic FL Tz probe is also useful for super resolution microscopy (SRM) imaging. 79,[87][88][89][90] In 2018 the Kele group reported uorogenic cyanine-tetrazine conjugates for no-wash subsequent super-resolution microscopy (STED) imaging of an actin lament. To quench the cyanine dye via the TBET strategy along with bioorthogonality, they designed 4 different tetrazinecyanine dyes utilizing either a phenylene or a vinylene linker between tetrazine and the uorophore.…”
Section: Tetrazine-based Turn-on Probementioning
confidence: 99%
“…The uorogenic FL Tz probe is also useful for super resolution microscopy (SRM) imaging. 79,[87][88][89][90] In 2018 the Kele group reported uorogenic cyanine-tetrazine conjugates for no-wash subsequent super-resolution microscopy (STED) imaging of an actin lament. To quench the cyanine dye via the TBET strategy along with bioorthogonality, they designed 4 different tetrazinecyanine dyes utilizing either a phenylene or a vinylene linker between tetrazine and the uorophore.…”
Section: Tetrazine-based Turn-on Probementioning
confidence: 99%
“…(B) Combining super-resolution techniques. Super-resolution techniques, such as stimulated emission depletion (STED), structured illumination microscopy (SIM) and stochastic optical reconstruction microscopy (STORM), provide a valuable starting point to study analytes in nano-dimension (Kozma and Kele 2018). Application of this technique to molecular probes for mapping metals is an important and arduous task.…”
Section: Summary and Perspectivesmentioning
confidence: 99%
“…fluorogens such as SiR-tubulin and SiR-actin) ( Fig. 4b, left) (80,81) or cell compartments directly (e.g. Membright, ER-Tracker or MitoTracker) ( Fig.…”
Section: Fluorescent Probe Development For Live-cell Super-resolutionmentioning
confidence: 99%