2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of So 2019
DOI: 10.1109/robomech.2019.8704756
|View full text |Cite
|
Sign up to set email alerts
|

Flyback Converter Controlled by Model-Based Current MPPT for a Photovoltaic Power System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Due to utilizing higher frequency signals, the reaction of the MPPT system is much faster and it results in faster transient response. This method does not guarantee to find In [73], researchers used the mathematical model of the system to calculate the output current of the solar panel. Similar to any other model-based method, dependency on the accurate model of the system is one of the main concerns in these types of methods.…”
Section: Ripple Correction Control (Rcc) Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to utilizing higher frequency signals, the reaction of the MPPT system is much faster and it results in faster transient response. This method does not guarantee to find In [73], researchers used the mathematical model of the system to calculate the output current of the solar panel. Similar to any other model-based method, dependency on the accurate model of the system is one of the main concerns in these types of methods.…”
Section: Ripple Correction Control (Rcc) Methodsmentioning
confidence: 99%
“…Experimental and simulation results confirm the correct operation of the system under various conditions. This algorithm utilizes digital filters and requires fast computations which are not a problem with the presence of the new technologies in the microcontrollers, the FPGAs, and the ASIC chips [73].…”
Section: An Overview On the Presented Methodsmentioning
confidence: 99%
“…To provide a contrast with the proposed strategy, a simulation is shown in Figure 5, in which the reference voltage is obtained from P&O MPPT strategy [24] with a 1 ms step for the MPPT and voltage reference changes ∆v of 0.1 V. The current reference i q (s) is considered to be 0 (no injected reactive power). The constant G ac corresponds to the converter gain, equal to 0.5.…”
Section: Cascade Controller Designmentioning
confidence: 99%
“…It is based on producing disturbances in a variable that operates as an actuator and subsequently evaluating how the power of the system evolves. It is possible to find different variations of the P&O strategy, where the variable to be modified will mainly depend on the energy storage element available in the power converter used [24]. For voltage source-type inverters, voltage disturbances are typically created, because the DCside capacitor operates as a voltage stabilizer [25,26].…”
Section: Introductionmentioning
confidence: 99%